HP A7143A RAID160 SA Controller Support Guide

Troubleshooting
The sautil Command
Chapter 6126
1+0, 5, ADG) logical drive have failed.
2) One or more disks in a RAID 0 logical drive have
failed.
3) Cache data loss has occurred.
4) Array expansion was aborted.
5) The logical drive is temporarily disabled because
another logical drive on the adapter had a missing disk
at power-up.
USING INTERIM RECOVERY MODE
Also known as "degraded" state. A physical disk in a fault
tolerant logical drive has failed. For RAID 1, 1+0 or 5,
data loss may result if a second disk should fail. For
RAID ADG, data loss may result if two additional disks
should fail.
READY FOR RECOVERY OPERATION
A replacement disk is present, but rebuild hasn’t started
yet (another logical drive may be currently rebuilding).
The logical drive will also return to this state if the
rebuild had been aborted due to unrecoverable read errors
from another disk.
RECOVERING One or more physical disks in this logical drive are being
rebuilt.
WRONG PHYSICAL DISK WAS REPLACED
While the logical drive was in a degraded state, the
system was powered off and a disk other than the failed
disk was replaced. Shut off the system and replace the