HP A7143A RAID160 SA Controller Support Guide

Installing the RAID160 SA Controller
Physical Disk Firmware
Chapter 488
# ioscan -kfn
Class I H/W Path Driver S/W State H/W Type Description
=============================================================================
root 0 root CLAIMED BUS_NEXUS
ioa 0 0 sba CLAIMED BUS_NEXUS System Bus
Adapter (582)
ba 0 0/0 lba CLAIMED BUS_NEXUS Local PCI Bus
Adapter (782)
lan 0 0/0/0/0 btlan CLAIMED INTERFACE HP PCI
10/100Base-TX Core
/dev/diag/lan0 /dev/ether0 /dev/lan0
target 2 0/0/1/1.15 tgt CLAIMED DEVICE
disk 0 0/0/1/1.15.0 sdisk CLAIMED DEVICE HP
73.4GMAN3735MC
/dev/dsk/c1t15d0 /dev/rdsk/c1t15d0
ext_bus 6 0/6/0/0 ciss CLAIMED INTERFACE PCI 4-Channel
RAID160 SA SCSI Adapter (A7143A)
/dev/ciss6
target 7 0/6/0/0.0 tgt NO_HW DEVICE
target 8 0/6/0/0.7 tgt CLAIMED DEVICE
The device file for the RAID160 SA controller in the example above is
/dev/ciss6.
Determining the SCSI Channel, the SCSI ID, and the
Firmware Version for Physical Disks
The SCSI channel, SCSI ID, and the firmware version that is installed
on each of the physical disks attached to the RAID160 SA controller can
be determined by using either the sautil <device_file> command
(extensive output), or the sautil <device_file> -s command
(shortened output).
An example of the lengthy sautil <device_file> command output is
provided in “The sautil Command” on page 115 in the Troubleshooting
chapter.