HP AD279A PCI 64-Port Serial Multiplexer Installation Guide, September 2006

HP PCI 64-Port Serial Multiplexer Adapter Installation
Verifying Hardware Installation
Chapter 1
11
Verifying Hardware Installation
After installing the hardware and software, you can verify the installation as follows:
A green light on the carrier LED indicates that hardware installation is successful and that the cable is
connected correctly.
Figure 1-3 shows the LED display on the port module.
Figure 1-3 LED Display
If the LED is blinking:
- Check whether the system is switched on, and the cables are properly connected.
- If the LED is off, check whether the driver is claimed by running the following command at the
command prompt:
$ ioscan -knfC tty
On-Line Addition and Replacement (OLAR) Operation on HP-UX 11i
v1 Systems
On-Line Addition and Replacement (OLAR) of AD279A PCI MUX 64-Port adapter is supported on HP-UX 11i
v1 operating systems.
Table 1-3 lists the HP-UX servers on which On-Line Addition and Replacement (OLAR) of AD279A PCI MUX
64-Port adapter is supported.
To add a new adapter or an additional adapter to a system that supports HP-UX 11i v1 operating system,
complete the following steps:
Table 1-3 OLAR Server Support
Server / Workstation OLAR Slot Support
rp4440 All slots
rp5450 Slot 7 to Slot 12
rp5470 Slot 5 to Slot 12
rp7410 All slots
rp7420 All slots