HP Fibre Channel Mass Storage Adapters Support Guide FibrChanl-01 (fcd) Driver HP-UX 11i v1, 11i v2, and 11i v3 HP Part Number: J6374-90085 Published: March 2011 Edition: Edition 1
© Copyright 2011 Hewlett Packard Development Company L.P Legal Notices The information in this document is subject to change without notice. Hewlett-Packard makes no warranty of any kind with regard to this manual, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose.
Contents 1 Adapter Overview......................................................................................5 HP Fibre Channel Mass Storage Overview...................................................................................5 2 Fibre Channel Adapter Installation................................................................6 Prerequisites.............................................................................................................................6 Installing Driver Software.....
Laser Safety Statements...........................................................................................................32 Certification and Classification Information............................................................................32 Product Information............................................................................................................32 Usage Restrictions.........................................................................................................
1 Adapter Overview HP Fibre Channel Mass Storage Overview NOTE: For the latest copy of this document and related HP Fibre Channel documentation: 1. Go tohttp://www.hp.com/go/hpux-iocards-docs 2. Select “ HP-UX 11i v1 I/O Cards”, “HP-UX 11i v2 I/O Cards”, or “HP-UX 11i v3 I/O Cards”, depending upon your version of HP-UX. HP Fibre Channel Mass Storage is a high-speed connection for mass storage. It transmits data faster than existing SCSI mass storage interconnects.
2 Fibre Channel Adapter Installation Prerequisites Before installing the adapter, follow these steps: 1. 2. Verify compliance with supported configurations using the HP Fibre Channel Host Bus Adapter Support Matrix at: http://www.hp.com/go/hpux-iocards-docs Determine if the adapter is a Customer Replaceable Unit (CRU) using the HP Fibre Channel Host Bus Adapter Support Matrix. If the adapter is not a CRU, contact your HP representative for installation assistance.
• A9784A PCI-X Combo 1-port 2Gb Fibre Channel and 1-port 1000Base-SX (fiber) Adapter • AB465A PCI-X Combo 2-port 2Gb Fibre Channel and 2-port 1000Base-T (copper) Adapter Table 1 (page 7) lists the bundle and product name for each adapter.
7. 8. 9. Select Mark for Install from the Actions menu. Select Install from the Actions menu. Installation begins and the Install Analysis window opens. Click OK in the Install Analysis window to confirm that you want to install the software. The Install window opens. View the Install window to read processing data while the software installs. When the Status field indicates Ready, the Confirmation window opens. 10. 11. 12. 13. Click OK. A second Confirmation window opens. Click OK again.
Install all driver software and dependent patches before you install the adapter. For more information, see FibrChanl-01 (fcd) Fibre Channel Mass Storage Driver for HP-UX 11i v3 Release Notes available at: http://www.hp.com/go/hpux-iocards-docs. NOTE: See the system documentation for information about how to safely shut down your system and obtain access to expansion slots. To install the Fibre Channel adapter, follow these steps: 1. 2. 3. 4. Install all driver software and dependent patches.
2. Verify that the correct drivers appear for each installed adapter. If all drivers display, proceed to the next section, “Verifying Connectivity” (page 10). Sample ioscan output: fc 0 0/0/2/1/0 fcd CLAIMED INTERFACE HP AB379-60001 4Gb Dual Port PCI/PCI-X Fibre Channel Adapter (FC Port 1) /dev/fcd0 fc 1 0/0/2/1/1 fcd CLAIMED INTERFACE HP AB379-60001 4Gb Dual Port PCI/PCI-X Fibre Channel Adapter (FC Port 2) /dev/fcd1 fcp 0 0/0/2/1/1.97 fcd_fcp CLAIMED INTERFACE FCP Domain ext_bus 2 0/0/2/1/1.97.5.19.
Example 1 Hardware Path for a Public Loop Device Adapter Domain Area Port Bus Target LUN 0/1/2/0.1.19.255.15.4.0 Example 2 Hardware Path for a Direct Fabric Attach Device Adapter Domain Area Port Bus Target LUN 0/1/2/0.1.19.255.0.0.0 Example 3 Hardware Path for a Private Loop Device Adapter Domain Area Port Bus Target LUN 0/1/2/0.8.0.255.0.1.0 Table 4 describes each field in the hardware path.
Table 4 Hardware Path Field Descriptions (continued) Fibre Channel Topology of HBA Field Value Fabric Topologies Target Depends on the Fibre Channel topology and the LUN addressing method used. Private Loop For LUNs with Peripheral Device With Peripheral Device Addressing, Addressing, the value of this field is the the value of this field is the lower 4-bits lower 4-bits of the third byte of the N_Port of the Loop ID of the target device. ID of the target device.
3 Troubleshooting and Maintenance Introduction Troubleshooting Fibre Channel problems can involve a variety of hardware and software components. A problem affecting the system may originate in another part of the Fibre Channel Mass Storage interconnect. If you cannot solve the problem on your own, contact your HP representative.
Table 6 A6826A LED States (continued) 2 Gb Link (Green) 1 Gb Link (Amber) Probable Cause Recommended Action Off On 1 Gb link-up No action is required. On Off 2 Gb link-up No action is required. Off 5 Flash/second Activity on 1 Gb link No action is required. 5 Flash/second Off Activity on 2 Gb link No action is required.
with dual port adapters, each port is accessed and configured independently through the appropriate device driver. CAUTION: The fcmsutil command is a powerful diagnostic tool that can cause problems if used incorrectly. Read and understand the manpage carefully before using fcmsutil. The primary fcmsutil options for system administrators are: • echo • test • reset • get For detailed information on this utility and its options, see the fcmsutil manpage.
Check to see that the driver state is ONLINE. You cannot use all fcmsutil options with all the adapters. In the manpage for fcmsutil, (QL) follows the options that can be used with the FibreChannel port of the A6826A, A9782A, A9784A, AB378A, AB379A, and AB465A adapters. Options without the (QL) indicator can be used with all adapters. You can use the echo, test, reset, and get options with fcmsutil. Use other fcmsutil options only at the request of your HP support representative.
Example 5 Sample VPD information, AB378A Adapter V I T A L --------- P R O D U C T ------------- D A T A ------- Product Description : HP PCI-X 2.0 4Gb Fibre Channel HBA Part number : AB378-60001 Engineering Date Code : X-4532 Part Serial number : JW45370268 Misc. Information : PW=15W;PCI=66MHZ;PCI-X=266MHZ Mfd. Date : 4537 Mfd. ID : AB378-60001 Check Sum : 0x4d EFI version : 01.01 ROM Firmware version : 04.00.70 BIOS version : 01.04 FCODE version : 01.
Example 6 Sample VPD information, AB379A Adapter V I T A L --------- P R O D U C T ------------- D A T A ------- Product Description : HP PCI-X 2.0 Dual Port 4Gb Fibre Channel HBA Part number : AB379-60001 Engineering Date Code : X-4602 Part Serial number : US00016362 Misc. Information : PW=15W;PCI=66MHZ;PCI-X=266MHZ Mfd. Date : 4602 Mfd. ID : FC2410401-10 04 Check Sum : 0xc5 EFI version : 01.01 ROM Firmware version : 04.00.70 BIOS version : 01.06 FCODE version : 01.
• AH401A • 403619-B21 • AD193A • AD194A • AD300A • AB378B • AB379B • AB378A • AB379A • A6826A • A9782A • A9784A • AB465A For more information on this command, see the fcmsutil (1M) manpage. When the fcd driver discovers a new target device, it creates a hardware path for that device based on the N_Port ID. The N_Port ID is the Fibre Channel address for a device, and a way of identifying the device in a Storage Area Network (SAN).
This command has three options: • Validate device replacement for a specific lunpath (for example, run the command: # scsimgr -f replace_wwid -C lunpath -I 0). The advantage of using this option is that it allows you to directly specify a single lunpath class and instance, and it is sufficient when the replaced device only has one lunpath, or if only a few lunpaths are affected by the SAN reconfiguration.
STM runs in three modes: • Menu Mode Use the mstm command to start STM in Menu Mode. • X Windows environment Use the xstm & command to start STM in X Windows. • Command Line Mode Use the cstm command to start STM in Command Line Mode. Three tools are available in STM for Fibre Channel Mass Storage adapters: • Information Tool The Information Tool provides information about a Fibre Channel adapter without resetting the adapter.
Generated EOF Count = 8 Bad CRC Count = 9 Protocol Error Count = 10 Possible Causes/Recommended Actions: It is possible for link down errors to occur under normal operation. No action is required. The system will recover. • Diagnose Tool The Diagnose Tool runs a loopback test on a Fibre Channel adapter. This test is destructive and must only be run by qualified personnel or on instruction from an HP Support Representative. NOTE: STM also includes a Firmware Update tool.
• A6826A • A9782A • A9784A • AB465A Installing and Configuring Support Tools Manager and EMS System requirements: • HP-UX computer (servers or workstations) • HP-UX 11i v1, 11i v2, 11i v3, or later HP-UX operating system versions • Support Plus Media CD • If you are using ServiceGuard (optional), check for the correct version you must have for HP-UX 11i v1, 11i v2 or later HP-UX operating system versions Procedure 1.
ODE consists of the following: Test Controller Acts as the user interface and launches the execution of the Test Modules. Test Modules Diagnostic or utility programs designed to execute within ODE. These modules exercise or diagnose user-specified hardware units. System Library (SysLib) A set of common routines for use by both the Test Controller and the Test Modules. These routines perform I/O, string parsing, and system control.
See the Support Matrix for the Fibre Channel adapter you are troubleshooting for current system and adapter firmware requirements and other information. Support Matrixes for HP Fibre Channel adapters are available at: http://www.hp.com/go/hpux-iocards-docs.
E. F. If the system firmware meets or exceeds the minimum required version, go to E. If not, go to G. Enter the swlist command to see if the Fibre Channel Mass Storage filesets have been installed. For example, enter swlist -l fileset. Does FC FILESET display? The file sets displayed depend on the Fibre Channel adapter product you are using.
Fibre Channel Connections Test Figure 2 Flowchart 2: Fibre Channel Connections Test Flowchart 2 Connections Test Procedures The sections below provide additional detail on the procedures listed in Flowchart 2. A. B. C. D. Verify that the Fibre Channel adapter is properly seated. Shut down the system by entering /usr/sbin/shutdown -h. Power off the system and disconnect the cables. Check that the adapter is properly seated in the backplane. To verify that it is seated correctly, power on the system.
E. F. Verify that the Fibre Channel Mass Storage device is powered on. If not, power on the device. Run Fibre Channel Mass Storage device-specific diagnostics. If diagnostics are available to troubleshoot the Fibre Channel Mass Storage device, follow the steps to verify that the device is functioning properly. After verification, go to Flowchart 3.
Firmware Updates This section explains the process for updating the firmware of your Fibre Channel host bus adapter. Fibre Channel Host Bus Adapter Online Firmware Updates The Fibre Channel host bus adapters that use the FCD driver can be updated while the system is online by using the rom_fw_update option of the fcmsutil command. CAUTION: Do not attempt to use the following procedure if the adapter is attached to a boot disk, swap, or dump device; this will result in a system hang.
1. 2. 3. 4. From the EFI prompt, enter the map -r command. Enter the cd command to change to the directory containing efiutil. Enter the efiutil command to get to the command line interface for efiutil. Choose the adapter you want to update as shown below: efiutil>adapter Adapter Index number [0]? Where: represents the adapter index you want to update. NOTE: Please note that the index number is the digit (0, 1, etc.) displayed by efiutil.
A Regulatory Statements This appendix contains the regulatory statements and declarations of conformity for the HP Fibre Channel host bus adapters. Regulatory Statements FCC Statement (USA Only) The Federal Communications Commission (in 47 CFR 15.105) has specified that the following notice be brought to the attention of the users of this product. This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules.
VCCI Statement (Japan) Figure 4 Japanese VCCI Statement Laser Safety Statements Certification and Classification Information This product contains a laser internal to the Optical Link Card/Optical Link Module (OLC/OLM) for connection to the Fibre communications port. In the USA, all models of the OLC/OLM are certified as Class 1 laser product and conform to the requirements contained in the Department of Health and Human Services (DHHS) Regulation 21 CFR subchapter J.
Laser Safety (Finland) LASERTURVALLISUUS LASERTURVALLISUUS LUOKAN 1 LASERLAITE KLASS 1 LASER APPARAT Fibre Channel 1063 MBaud Optical Link -kortille on asennettu optista tiedonsiirtoa varten laserlähetin, joka lähettää signaalit siihen kytketyn optisen kuidun kautta. Normaalissa toimintatilassa lähetin on käyttäjälle turvallinen luokan 1 laserlaite, eikä käyttäjä voi altistua sen lähettämälle säteilylle. Optisen lähetinmoduulin turvallisuusluokka on määritetty standardin EN 60825 (1991) mukaisesti.
B Additional Features This chapter discusses the SNIA Application Programming Interface that can be used with the Fibre Channel Host Bus Adapters. Fibre Channel SNIA HBA API Software applications managing SANs require information from host bus adapters (HBAs) to operate. Every vendor, operating system, and platform provides HBA information differently.
Index A A6684A HSC Tachlite adapter, 23 installing software, 7 A6685A HSC Tachlite adapter, 23 installing software, 7 A6795A FC PCI XL2 adapter, 6 adapter LEDs A3591A/B, 13 A5158A, 13 A6684A, 13 A6826A, 13, 14 AL_PA, 12 Arbitrated Loop Physical Address (AL_PA), 12 C cable products, 9 cabling requirements, 6 customer replaceable units (CRUs), 6 D diagnose tool, 22 diagnostic flowcharts flowchart 1, configuration test, 25 flowchart 2 procedures, 25 flowchart 2, FC connections test, 27 flowchart 3 procedures