HP Smart Array SAS Controllers for Integrity Servers Support Guide

Table 20 Smart Array controller POST error codes (continued)
Corrective actionLevelDescriptionError
code
None.NoneSlot z Drive Array Disk Performance
Optimization Scan in Progress RAID 4/5/ADG
performance may be higher after completion.
1729
No F1 prompt if disable reason is
rebuild running.
Informational or
None
Slot z Drive Array - Capacity Expansion Process
is Temporarily Disabled (followed by one of the
following):
1764
Expansion will resume when Array Accelerator
has been reattached.
Expansion will resume when Array Accelerator
has been replaced.
Expansion will resume when Array Accelerator
RAM allocation is successful.
Expansion will resume when Array Accelerator
battery reaches full charge.
Expansion will resume when Automatic Data
Recovery has been Completed.
None.NoneSlot z Drive Array resuming Logical Drive Capacity
Expansion process.
1768
Press F1 to continue with logical drives
disabled. See Chapter 4 (page 59).
CriticalSlot z Drive Array - Drive(s) Disabled due to Failure
During Expansion (possibly followed by one of the
following additional details:)
1769
Press F2 to accept data loss and to
re-enable logical drives.
Array Accelerator Removed or Failed;
Expansion Progress Data Lost.
Warning: Pressing F2 causes
unrecoverable data loss. Be sure you
Expansion Progress Data Could Not Be Read
From Array Accelerator.
have a valid, current backup of the
affected logical drives before selecting
this option.
Expansion Aborted due to Unrecoverable Drive
Errors.
Expansion Aborted due to Array Accelerator
Errors.
Upgrade the firmware of the affected
drive.
InformationalSlot z Drive Array Critical Drive Firmware
Problem Detected - Please upgrade firmware on
1770
the following drive(s) using Options ROMPaq
(available from www.hp.com):
Port 1I: Box 1: Bay 1
None.InformationalSlot z Drive Array - Obsolete Data found in Array
Accelerator. Data Found in Array Accelerator was
1774
Older Than Data Found on Drives Obsolete Data
has been Discarded
Correct the cabling problem identified
in the error message.
InformationalSlot z Drive Array - Storage Enclosure Cabling
Problem Detected. OUT port of this box is attached
1775
to OUT port of previous box. Turn system and
storage box power OFF and check cables. Drives
in this box and connections beyond it will not be
available until the cables are attached correctly.
Port 1I: Box 2
None.NoneSlot z Drive Array resuming Automatic Data
Recovery process.
1778
Restore data from backup if
replacement drives have been
installed.
CriticalSlot z Drive Array -Replacement drive(s) detected
OR previously failed drive(s) now appear to be
operational:
1779
Port 2I: Box 1: Bay 2
112 Power-on Self Test (POST) error codes