RAID-01 (ciss) B.11.23.1003 Mass Storage Driver Release Notes, Edition 2 (March 2010)

2.2 Changed Features
There are no changed features included in RAID-01 at the time of this publication.
3 Problems Fixed in This Version
Table 2 lists the problems fixed in this version of RAID-01.
Table 2 HP-UX 11i v2 Month_Year Fixes RAID-01 Bundle_Version
DescriptionSR Number
With INCPTR.BIN firmware version 7.02, a crash occurs when the Smart Array heartbeat
has not incremented in the last 5 secs.
QXCR1000980558
The sautil utility does not check the battery count when a RAID 6 (ADG) volume is
created.
QXCR1000945054
Problems Fixed in Recent Versions
There were no defects or fixes included in RAID-01 version B.11.23.0806.
4 Known Problems and Limitations
This section provides a list of problems and limitations known to HP when these release notes
were published. If workarounds are available, they are included.
4.1 For All Smart Array Controllers
Automatic hot-plug issue.
The HP Smart Array Controllers do not automatically detect hot-plug of internal disks.
Corrective Action: After replacing a physical disk, run the sautil command with the scan
option.
4.2 For SAS (Serial-Attached SCSI) Smart Array Controllers Only
The intctl command does not display interrupt information for Smart Array P400 and
P800 controllers
On systems with RAID-01 B.11.23.0806 installed, intctl does not display interrupt
information for Smart Array P400 and P800 controllers. The interrupt migration feature is
not supported for these controllers.
SAS Storage Enclosure Status display issue in sautil command output.
SAS storage enclosures (SES devices) and their status appear in the outputs of sautil
/dev/cissX (extensive output) or sautil /dev/cissX -s (shortened output) commands.
Devices appear in the SAS/SATA DEVICE SUMMARY section, and in the detailed information
provided for each DISK device and SES device in the command output.
The status of a SAS SES device is always FAILED. The FAILED status does not indicate that
the enclosure is not functioning. It means that it is not a DISK device.
Corrective Action: None. You can continue to use the SAS storage enclosures. You can also
use sautil to download enclosure firmware when needed.
For more information, see the HP Smart Array P400 and P800 Controller Support Guide at:
http://docs.hp.com/en/netcom.html
HP-UX installation issue.
Installation of HP-UX 11i v2, OE0706 fails when installing to an array of eight 146 GB SAS
disks configured as a single RAID 0 logical volume.
4