10GigEthr-02 (iexgbe) B.11.31.1303 Ethernet Driver Release Notes (Edition 2)

4 Known problems and limitations
The following problems and limitations are known to exist in version B.11.31.1303:
QXCR1001270195 iexgbe 1303 versions introduced issues due to missing firmware lock
The following symptoms might be seen because of this defect:
iexgbe driver continuously sends UP/DOWN notification events to the WBEM provider.
(QXCR1001268673) The WBEM events seen by the user are of these types:
DL_HP_EXT_LINK_DOWN_IND and DL_HP_EXT_LINK_UP_IND.
(QXCR1001267062) The nettl log becomes filled with link EPHY8073 link up
notification messages.
The following is an example of the messages seen:
<4006> 10GBase-SR in path 0/0/0/3/0/0/5
Link Event.
EPHY8073 link up or
<4006> 10GBase-SR in path 0/0/0/3/0/0/5
Link Event.
EPHY8726 link up
(QXCR1001268375) Speed mismatch error frequently recorded in syslog.
The driver can present the following message in syslog during DLKM load/unload,
boot, or other control path operations:
internal_link_settings_status: 10G speed mismatch 0x300
(QXCR1001268375) Ports for which the adapter reports the incorrect speed might
occasionally cause APA formation to fail during startup.
iexgbe m45write and m45read message logged on the console.
(QXCR1001267051) During DLKM load/unload, the following message might be seen
on the console:
...m45write: Setting PHY address to write failed, phyreg 0xffe4, devad 0x7, val 0x1e0
...m45read: Setting PHY address to read failed 0x2227ffe4 0x1
(QXCR1001265402) During installation or deinstallation of the 10GigEthr-02 bundle,
the following message might be seen:
...m45read: Read of PHY register failed, addr 0x2227ffe4 init_done 1,
status 0x2e270000
QXCR1001267697 Problem with nwmgr -s -A all --sa --fr cu -c command
The command does not properly store the parameter settings in the
/etc/rc.config.d/hpiexgbeconf configuration file.
QXCR1001247823 iexgbe driver intermittently stops collecting/incrementing link statistics
The iexgbe driver intermittently stops collecting and updating link statistics. This does not
affect data traffic; it only affects statistics. However, this can cause false link failure detection;
systems with MC/Serviceguard might exhibit a system Transfer Of Control (TOC), thereby
inhibiting Serviceguard recovery from a link outage or network connectivity problem.
Severity: Medium
Workaround: Resolve the problem by resetting the link. Statistics will then be collected and
updated properly.
10