FibrChanl-01 (fcd) Fibre Channel Mass Storage Driver for HP-UX 11i v3 Release Notes Version Number B.11.31.1203 HP Part Number: 5900-2252 Published: March 2012 Edition: 2.
Contents FibrChanl-01 (fcd) Fibre Channel Mass Storage Driver for HP-UX 11i v3 overview..............................3 New and changed features in this release...................................................................................3 New features......................................................................................................................3 Changed features................................................................................................................
This document provides information about the B.11.31.1203 release of the FibrChanl-01 (fcd) Fibre Channel Mass Storage Driver for HP-UX 11i v3. FibrChanl-01 (fcd) Fibre Channel Mass Storage Driver for HP-UX 11i v3 overview This release of the document for the FibrChanl-01 (fcd) Fibre Channel Mass Storage Driver for HP-UX 11i v3 (version B.11.31.1203) documents version changes and defect fixes. New and changed features in this release New features There are no new features in this release.
Table 3 HP-UX May 2011 (WEB1105) Fixes Defect ID Description QXCR1001123656 This fixes an issue in Qlogic 8Gb FC Firmware that enables it to use correct slot-specific SerDes settings for the 8Gb PCIe Dual Port Mezzanine Fibre Channel Adapter. Table 4 HP-UX March 2011 (AR1103) Fixes Defect ID Description QXCR1001020559 SNIA: FC Instance Enumeration FCPortControllerCollection fails if port disabled. QXCR1001073517 SNIA: FC Provider dumps core during CHO test.
Table 7 HP-UX March 2010 (WEB1003) Fixes Defect ID Description QXCR1000887704 This fixes an issue where the SNIA returns HBA_STATUS_ERROR for HBA_SendCTPassThru API call failure. QXCR1001007011 This fixes a Serviceguard “safety timer” panic on a single-cpu vpar configuration, when the command fcmsutil_ns_query_port is executed. QXCR1000994941 This fixes the issue in the fcd driver that can intermittently result in a mailbox timeout fatal error.
Table 12 HP-UX September 2008 Fixes Defect ID N/A Description There are no fixes for the September 2008 release. Table 13 HP-UX March 2008 Fixes Defect ID Description QXCR1000754446 Added Symbolic Name support. Symbolic Names are user friendly names assigned to SAN components, and registered with the name server of an FC switch. FC switches display the registered symbolic names, which can be used by users to correlate SAN components across multiple servers and storage.
In aborting an I/O that is active with a FC target device, the FibrChan-01 (fcd) driver must wait for a period equal to the value of R_A_TOV before returning the I/O with aborted status to the mass storage stack. This means the new path addition and subsequent retry of I/O is delayed for a period equal to the value of R_A_TOV. This could result in applications that access the LUN experiencing I/O timeouts during new LUN path addition.
3. 4. 5. 6. • Type Type Type Type CM to enter the Command Menu. DF to enter the Display FRU Information Menu. S to display a list of specific FRUs. 05 for the I/O Assembly FRU. ◦ For AD295A #200, AD296A #200, and AD298A, the Product Name displays as: 10 Slot PCI-E IOBP ◦ For AD295A #300, AD296A #300, and AD230A, the Product Name displays as: 10 Slot PCI-E 1.
OLR occurs when performing a replacement operation with the olrad command, PCI attention button, or the System Management Homepage (SMH) on systems with this OLR feature. OLD occurs when performing a delete operation with the olrad command, or with the Systems Management Homepage (SMH) on systems with this OLD feature. A dynamic module unload can occur with kcmodule, swinstall, or swremove commands.
1. 2. 3. • From the EFI shell: Manually issue the EFI shell command reconnect —r, before attempting to boot from the alternate path. Online: Use the HP-UX setboot command to swap the primary and alternate boot devices. Hardware configuration: Reconfigure by moving the alternate boot device to a different HBA.
Driver bundles can be downloaded from the HP Software Depot at: http://www.software.hp.com Patches are available from either: http://www.software.hp.com or http://itresourcecenter.hp.com OnlineDiag is available at http://www.software.hp.com in the Enhancement releases and patch bundles section, or on the HP-UX 11i v3 OE media (December 2004 and later). Requirements for Boot Support: 451871-B21, AH400A/AH401A, AD193A/AD194A, 403619–B21, AD300A, AB378A, AB378B, AB379A, AB379B, A6826A.
Table 16 Table of Driver Versions Release Name Driver Version Release Date Initial 11.31 Support B.11.31 February 2007 Application Release 0709 B.11.31.0709 September 2007 Application Release 0803 B.11.31.0803 March 2008 Application Release 0809 B.11.31.0809 September 2008 Application Release 0903 B.11.31.0903 March 2009 Application Release 0909 B.11.31.0909 September 2009 Application Release 1003 B.11.31.1003 March 2010 Web Release 1003 B.11.31.1003.
Related information The latest documentation for the FibrChanl-01 (fcd) Fibre Channel Mass Storage Driver for HP-UX 11i v3 is available at http://www.hp.com/go/hpux-iocards-docs, under the HP Fibre Channel Host Bus Adapters section. Available documents include: • Support Guide: includes an adapter overview, installation details, adapter configuration, troubleshooting and maintenance information, additional features, and regulatory information.