FibrChanl-02 (fclp) Fibre Channel Mass Storage Driver for HP-UX 11i v3 Release Notes Version Number B.11.31.1303 HP Part Number: 5900-30067 Published: March 2013 Edition: 1.
Contents FibrChanl-02 (fclp) Fibre Channel Mass Storage Driver for HP-UX 11i v3 overview.............................3 New and changed features in this release...................................................................................3 New features......................................................................................................................3 Known problems fixed in this version...........................................................................................
This document provides information about the B.11.31.1303 release of the FibrChanl-02 (fclp) Fibre Channel Mass Storage Driver for HP-UX 11i v3. FibrChanl-02 (fclp) Fibre Channel Mass Storage Driver for HP-UX 11i v3 overview This release of the document for the FibrChanl-02 (fclp) Fibre Channel Mass Storage Driver for HP-UX 11i v3 (version B.11.31.1303) documents defect fixes and version changes. New and changed features in this release New features The following feature is new with the B.11.31.
Table 2 HP-UX September 2012 (AR1209) Fixes (continued) Defect ID Description QXCR1001226959 This fixes a timing-related issue in the FCLP driver that may cause a system panic when a driver internal error occurs while the driver is being reset. QXCR1001184198 This fixes a timing-related issue in the FCLP driver that may cause a system panic when a driver internal error occurs while the driver is being reset.
Table 6 HP-UX September 2011 (AR1109) Fixes (continued) Defect ID Description QXCR1001094073 This change will log an Event Monitoring Service (EMS) event and syslog information whenever a Fibre device comes back in the Name Server. QXCR1001123527 This fixes the issue where the fclp driver may panic with “Bad News!” when an fcmsutil command is run at the same time that the fclp driver is being reset.
Table 10 HP-UX March 2010 (WEB1003) Fixes Defect ID Description QXCR1000972188 Corrected a timing-related fclp driver issue that caused an inconsistent driver state. When the QXCR1000947409 driver detected this inconsistent state, it would reset the HBA unexpectedly. QXCR1000980397 QXCR1000978071 Modified the fclp uninitialization sequence to correct hangs that would occur during driver unload. QXCR1000946402 These hangs would only occur if I/O was in progress when the unload was initiated.
Table 17 HP-UX September 2008 Fixes Defect ID Description QXCR1000799018 Fixed an issue which caused system dump failure to an fclp attached device, if base page size was set to a value other than 4 KB. QXCR1000753480 Long hardware path from AD221A (PCIe 1 port 4Gb FC and 1 port GigE HBA) card not recognized by vparmodify. The workaround for this issue is located at this address:http:// docs.hp.com/en/T1335-90091/ar01s05.html NOTE: 11i v3. AR0803 (Version B.11.31.
(C) Copyright 1999-2006 Hewlett-Packard Development Company, L.P. All rights reserved HP-UX Boot Loader for IPF -- Revision 2.029 Press Any Key to interrupt Autoboot \EFI\HPUX\AUTO ==> boot vmunix Seconds left till autoboot 0 AUTOBOOTING...Could not open file vmunix to check for a directory Could not open vmunix loading failed HPUX> This issue is addressed in system firmware version 3.01 for rx2660, rx3600, and rx6600. There are three workarounds for this issue: 1.
1. 2. 3. 4. 5. 6. 7. 8. 9. • To view the Emulex driver handle information, type Shell> drivers at the EFI shell prompt - - a list of drivers is displayed. Write down the driver handle associated with the Emulex SCSI Pass Thru Driver. The first column, labelled DRV, lists the driver handles. Enter the drvcfg -s command; for example, if the driver handle is 20 (your driver handle may be different): Shell> drvcfg -s 20.
OnlineDiag is available at http://www.software.hp.com in the Enhancement releases and patch bundles section, or on the HP-UX 11i v3 OE media. Installation instructions are available at: http:// www.hp.com/go/hpux-iocards-docs, by clicking onHP Fibre Channel Host Bus Adapters. Requirements for boot support To boot through the fibre channel ports on these adapters, HP recommends that you update the EFI driver and onboard firmware to the latest version.
Table 19 Table of Driver Versions (continued) Release Name Driver Version Release Date Application Release 1009 B.11.31.1009 September 2010 Application Release 1103 B.11.31.1103 March 2011 Web Release 1104 B.11.31.1104 April 2011 Application Release 1109 B.11.31.1109 September 2011 Web Release 1108 (supersedes AR1109) B.11.31.1109.01 August 2011 Application Release 1203 B.11.31.1203 March 2012 Web Release 1204 B.11.31.1204 April 2012 Application Release 1209 B.11.31.
It is not possible to update previous recipes/versions of the Mezzanine card to be compatible with the HP Integrity blades. Identification These are the ways to identify the versions of the cards that are compatible with Integrity c-Class blades. EDC change Newer cards are built with an Engineering Date Code that marks the changes required for Integrity — Integrity-supported versions have an EDC of B-4813 or later.
Engineering Date Code : "B-4813" Mfd. Date : "4807" Misc. Information : "PW=6.5W; PCIe x4 Gen1" ROM Firmware version : "2.72A2 SLI-3 (Z3F2.72A2)" EFI version : "ZU6.00A5" Card revision Although EDC is the primary way to identify changes in recipe for Integrity systems, it is also possible to use the card “Rev”, which is printed on a label on the box containing the card, and on a label on the card. CAUTION: There are at least three different “Rev” identifiers on the card.
Related information The latest documentation for the FibrChanl-02 (fclp) Fibre Channel Mass Storage Driver for HP-UX 11i v3 is available at http://www.hp.com/go/hpux-iocards-docs, by clicking onHP Fibre Channel Host Bus Adapters. Available documents include: • Support Guide: includes an adapter overview, installation details, adapter configuration, troubleshooting and maintenance information, additional features, and regulatory information.