FibrChanl-03 (fcoc) Fibre Channel Mass Storage Driver for HP-UX 11i v3 Release Notes Version Number B.11.31.1109.02 HP Part Number: 5900-1963 Published: November 2011 Edition: 1.
Contents FibrChanl-03 (fcoc) Fibre Channel Mass Storage Driver for HP-UX 11i v3 overview............................3 New and changed features in this release...................................................................................3 New features......................................................................................................................3 Known problems fixed in this version...........................................................................................
This document provides information about the B.11.31.1109.02 release of the FibrChanl-03 (fcoc) Fibre Channel Mass Storage Driver for HP-UX 11i v3. FibrChanl-03 (fcoc) Fibre Channel Mass Storage Driver for HP-UX 11i v3 overview This release of the document for the FibrChanl-03 (fcoc) Fibre Channel Mass Storage Driver for HP-UX 11i v3 (version B.11.31.1109.02) documents defect fixes and version changes. New and changed features in this release New features This feature is new with the B.11.31.1109.
Table 2 HP-UX September 2011 (AR1109) Fixes (continued) Defect ID Description For the FlexFabric Adapter NC551m (580151-B21), the minimum firmware version required to access this fix is 2.704.322.0. Table 3 HP-UX March 2011 (WEB1103) Fixes Defect ID Description QXCR1001070913 This release fixes a problem in which when a port is disabled, SNIA does not display any port or adapter attributes for other enabled ports.
1. Launch the Device Manager. A front page is displayed. 2. 3. Select Emulex Configuration Utility Ver:X.XXXXX and press Enter. When the Emulex Configuration Utility screen is displayed with Emulex Configuration Setup Utility selected, press Enter. 4. A list of all the adapters in the system is displayed. Your list may vary depending on the installed adapters. Locate the adapter you want to configure. Use the up/down arrows on your keyboard to select it, and press Enter.
5. The Emulex Adapter Configuration Main Menu screen comes up. Select Set Boot From SAN. A Disable Enable menu is displayed. Use the arrow keys to select the Enable option and press Enter. The selection is updated to NVRAM and the current setting is displayed. 6. On the same Emulex Adapter Configuration Main Menu screen, select Back to Display Adapters and RECONNECT DEVICES and press Enter. Type s to save the changes. Exit the Emulex utility. Control B to go into cm and type rs to reset the system. 7.
• rx2800 i2 System Firmware s26.21 or higher • C7000 OA Firmware 3.20 or higher • VCSU FW 1.6.0 or higher • VC-Enet FW Version 3.15 or higher (for profile migration, 3.17 or higher is required) • NC551m Firmware version 2.104.356.3 or higher • NC553m Firmware version 3.104.356.3 or higher • CN1100E Firmware version 3.104.356.3 or higher • HP-UX 11i v3 OS Fusion version B.11.31.1103 or higher • HP-UX CommonIO 11.31.1103 (B.11.31.
Hardware Requirements This version of the FibrChanl-03 (fcoc) Fibre Channel Mass Storage Driver for HP-UX 11i v3 runs on HP Integrity BL8x0c i2, rx2800 i2, and Superdome2 servers with the HP-UX 11i v3 (B.11.31) operating system.