HP-UX vPars and Integrity VM V6.3 Administrator Guide

Example 8 Enumeration being enabled for all NPIV devices
- - - - - - - - - - Prior Console Output - - - - - - - - - -
FPSWA.EFI start successful.
EFI Boot Manager ver 1.10 [14.62] [Build: Tue Oct 2 03:33:06 2012]
Loading device drivers
EFI Boot Manager ver 1.10 [14.62] [Build: Tue Oct 2 03:33:06 2012]
Please select a boot option
EFI Shell [Built-in]
Boot option maintenance menu
Use ^ and v to change option(s). Use Enter to select an option
- - - - - - - - - - - - Live Console - - - - - - - - - - - -
Loading.: EFI Shell [Built-in]
EFI Shell version 1.10 [14.62]
Device mapping table
Shell>
Shell> drvcfg -s
Set Configuration Options
Drv[13] Ctrl[ALL] Lang[eng] - Options not set. Status = Invalid Parameter
HP AVIO Stor Driver Configuration
==================================
Warning: Enumerating all SCSI or FC LUNs increases initialization times.
Enumerate all SCSI LUNs (Y/N)? [current setting: N]: Y
Enumerate all FC LUNs (Y/N)? [current setting: N]: Y
Drv[2A] Ctrl[ALL] Lang[eng] - Options set. Action Required is None
Shell> reset
Please select a boot option
EFI Shell [Built-in]
Boot option maintenance menu
Use ^ and v to change option(s). Use Enter to select an option
Loading.: EFI Shell [Built-in]
EFI Shell version 1.10 [14.62]
Device mapping table
blk0 : Acpi(PNP0A03,0)/Pci(5|0)/Fibre(WWN50001FE150100278,Lun4001000000000000)
blk1 : Acpi(PNP0A03,0)/Pci(5|0)/Fibre(WWN50001FE150100278,Lun4002000000000000)
blk2 : Acpi(PNP0A03,0)/Pci(5|0)/Fibre(WWN50001FE150100279,Lun4001000000000000)
blk3 : Acpi(PNP0A03,0)/Pci(5|0)/Fibre(WWN50001FE150100279,Lun4002000000000000)
blk4 : Acpi(PNP0A03,0)/Pci(5|0)/Fibre(WWN50001FE15010027C,Lun4001000000000000)
blk5 : Acpi(PNP0A03,0)/Pci(5|0)/Fibre(WWN50001FE15010027C,Lun4002000000000000)
NOTE: Selecting enumeration of NPIV devices at EFI increases the vPar or VM guest boot time.
After the NPIV boot device is configured, HP recommends that the FC (NPIV) LUN enumeration be
switched off again.
7.4.3.6 Installing the guest image on NPIV disks
After the LUNs are presented to the NPIV HBA, the vPar and VM guest image can be installed on
an NPIV device. After the NPIV device is enumerated and selected at EFI shell, installing vPar or
VM guest images on it is same as the HP-UX installation process.
7.4.3.7 Identifying NPIV HBAs and devices in a guest
To identify an NPIV HBA from the set of HBAs in the guest, use the ioscan command.
7.4 Configuring an NPIV HBA (vHBA) 107