HP-UX vPars and Integrity VM V6.3 Administrator Guide

Figure 11 Multi-pathing with NPIV devices
Integrity VM / Virtual Partition
Virtualization Services Platform (VSP)
HBA 1
IIIIIIIIIIII
pFC1
vFC1
pFC2
HBA 2
IIIIIIIIIIII
pFC3
vFC2 vFC3
pFC4
vFC1 vFC3vFC2
NPIV Disk
SAN Fabric
SAN LUN
NOTE: Having multiple paths to an NPIV device through the same physical HBA port on the VSP
does not fetch the benefits of multi-pathing because all paths will be using the same physical port
for IO traffic and thereby not provide any redundancy.
All aspects of native multi-pathing for regular FC device on a physical host is applicable to an
NPIV device seen in the guest. For more information about native multi-pathing on HP-UX, see
Native Multi-Pathing for Mass Storage technical white paper at
nl
http://www.hp.com/go/hpux-hpvm-docs.
7.5 Migrating VM guests with NPIV HBAs
vPars and Integrity VM 6.1.5 and later versions support online migration of VM guests and offline
migration of vPars and VM guests with NPIV HBAs across an FC fabric. After the migration, the
NPIV HBAs of a particular guest might not always be spread across different pFCs ports or adapters
on the target host. For more information about the modified behavior, see Section 12.3.4.4
(page 213).
7.5 Migrating VM guests with NPIV HBAs 109