HP-UX vPars and Integrity VM V6.3 Administrator Guide

dscvr_g02# ioscan -kfNd gvsd
Class I H/W Path Driver S/W State H/W Type Description
======= ========== ====== ========= ========= ======================
ext_bus 0 0/0/0/0 gvsd CLAIMED INTERFACE HPVM NPIV Stor Adapter
dscvr_g02# hpvmdevinfo
Device Bus,Device,Target Backing Store Host Device Virtual Machine
Type Type Name Device Name
====== ================= ============= =========== ===============
hba [0,0] npiv/dev/fcd4 /dev/gvsd0
dscvr_g02# setboot
Primary bootpath : 0/0/0/0.0x21530002ac000d2c.0x4001000000000000(/dev/rdisk/disk0)-------------> Boot disk
HA Alternate bootpath :
Alternate bootpath :
dscvr_g02# ioscan -m lun /dev/rdisk/disk0
Class Lun H/W Path Driver S/W State H/W Type Health Description
I
====== ==== ============== ====== ========= ======== =================
disk 0 64000/0xfa00/0x1 esdisk CLAIMED DEVICE online 3PARdataVV
0/0/0/0.0x21530002ac000d2c.0x4001000000000000 -------------> Boot disk has a single path
/dev/disk/disk0 /dev/disk/disk0_p2 /dev/rdisk/disk0 /dev/rdisk/disk0_p2
/dev/disk/disk0_p1 /dev/disk/disk0_p3 /dev/rdisk/disk0_p1 /dev/rdisk/disk0_p3
OLR Operation:
To do an online replacement of the card in slot 10-0-1-1-0-5 (/dev/fcd4 and /dev/fcd5), first run
the olrad command to determine the criticality of the resource.
VSP# olrad -C 10-0-1-1-0-5
Critical Resource Analysis(CRA) in progress...
[NOTE: The CRA may take a few minutes to complete on large
configurations. It is recommended not to disrupt this operation.]
CRA REPORT SUMMARY: CRA detected SYSTEM CRITICAL usages.
Detailed CRA report is available in /var/adm/cra.log file.
The CRA reports SYSTEM CRITICAL severity, for more information about SYSTEM CRITICAL severity,
see the CRA log. The following is the snippet from the CRA log on the VSP containing the NPIV
analysis:
ANALYSIS SCOPE: HPVM NPIV
This report provides details of any critical NPIV hardware path usages in the system.
RESULT: SYSTEM CRITICAL NPIV resources will be affected
DETAILED HPVM NPIV CRA REPORT
SYSTEM CRITICAL RESULTS
Affected vPars or VM guest are:
2 -----------> VM guest dscvr_g02
DATA CRITICAL RESULTS
Affected vPars or VM guest are: NONE
WARNINGS
Affected vPars or VM guest are:
1 -----------> VM guest dscvr_g01
FAILURE
vPars or VM guests that failed to perform CRA analysis are: NONE
The CRA logs inside VM guests dscvr_g01 and dscvr_g02 have the additional information
about why the CRA analysis within the VM guests reported WARNING and SYSTEM CRITICAL
respectively.
172 PCI OLR support on VSPs