HP-UX vPars and Integrity VM V6.3 Administrator Guide

# diskinfo /dev/rdisk/disk7
SCSI describe of /dev/rdisk/disk7:
vendor: HP
product id: Virtual DVD
type: CD-ROM
size: 665600 Kbytes
bytes per sector: 2048
vMP> ej
Ejectable Guest Devices
Num Hw-path (Bus,Slot,Tgt) Gdev Pstore Path
-------------------------------------------------------------------------
[1] 0/0/1/0.7.0 (0,1,7) dvd disk /dev/rdisk/disk7
Enter menu item number or [Q] to Quit: 1
Confirm eject action
G - Go
F - Force
Enter menu item or [Q] to Quit: G
vMP> co
# diskinfo /dev/rdisk/disk7
SCSI describe of /dev/rdisk/disk7:
vendor: HP
product id: Virtual NullDVD
type: CD-ROM
size: 0 Kbytes
bytes per sector: 0
vMP>
After inserting a new disk on the VSP CD or DVD drive, enter the following:
vMP> in
Insertable Guest Devices
Num Hw-path (Bus,Slot,Tgt) Gdev
--------------------------------------------
[1] 0/0/1/0.7.0 (0,1,7) dvd
Enter menu item number or [Q] to Quit: 1
Insertable File Backing Stores
Num File
---------------------
[1] /dev/rdisk/disk7
Enter menu item number or [Q] to Quit: 1
Confirm insertion action
G - Go
F - Force
Enter menu item or [Q] to Quit: G
vMP> co
# diskinfo /dev/rdisk/disk7
SCSI describe of /dev/rdisk/disk7:
vendor: HP
product id: Virtual DVD
type: CD-ROM
size: 4300800 Kbytes
bytes per sector: 2048
NOTE: Guest operating systems, applications, or configuration files sensitive to device names
or hardware paths must be repaired after the move. Because HP-UX 11i v3 supports the agile
device naming model, 11i v3 guest applications using agile device names are not affected as
long as they are configured with disk backing stores.
6.5 Using vPars and Integrity VM storage 97