Interface Card Critical Resource Analysis(CRA) Whitepaper for HP-UX 11i v3

stop the SG cluster service, a different quorum disk can be configured using an alternative healthy
card and the required olrad operation can be performed.
Scenario 10
System Configuration:
HP-UX OS running in Service Guard (SG) cluster environment with common
lock disk between the cluster nodes, and the cluster is configured with a common lock disk using path
dependent device special file.
Operation Performed:
# rmsf -L
Criticality reported by CRA:
CRA_SYSTEM_CRITICAL
Explanation and user action required:
The above rmsf operation will render the quorum disk unavailable if the requested operation is
allowed to proceed. Since this will result in the node being evicted from the cluster and because the
proper functioning of the SG cluster is considered one of the critical configurations, the above
requested operation will not be allowed by CRA to proceed and the operation will fail with a
CRA_SYSTEM_CRITICAL error.
If the quorum disk has been configured using path dependent device special file, it will not be
possible to provide an alternative path to the quorum disk without losing the SG cluster functionality
and hence the requested operation is not recommended.
However, if the user is prepared to stop the SG cluster service, a quorum disk can be configured
using path-independent DSF, which has one or more lunpaths to the quorum disk and the above
operation can be performed.
Scenario 11
System Configuration:
HP-UX OS running in Service Guard (SG) cluster environment with common
lock disk between the cluster nodes, and the cluster is configured with a common lock disk, which has
one or more lunpath(s) through I/O cards controlled by the same driver.
Operation Performed:
# kcmodule <interface driver associated with card>=unused
Criticality reported by CRA:
CRA_SYSTEM_CRITICAL
Explanation and user action required:
The above operation will render the quorum disk unavailable if the requested operation is allowed to
proceed. Since this will result in the node being evicted from the cluster and the proper functioning of
the SG cluster is considered as one of the critical configurations, the above requested operation will
not be allowed by CRA to proceed and the operation will fail with CRA_SYSTEM_CRITICAL error.
If this operation must be performed for system administration purposes, then, before performing the
above operation, the user must configure another lunpath to the SG quorum disk through a card
controlled by a different I/O driver. However, this is possible only if the quorum disk has been
configured using path-independent device special file (DSF).
If the quorum disk has been configured using a path dependent device special file, it will not be
possible to provide any alternative path to the quorum disk without losing the SG cluster functionality
and hence the requested operation is not recommended to be performed. However, if the user is
prepared to stop the SG cluster, and an alternative path to the quorum disk can be configured
through a card controlled by different I/O driver, then the required operation can be performed.
11