HP WBEM Services Version A.02.09.12 Release Notes (5900-2121, March 2012)

Table 4 Defects fixed in HP WBEM Services Version A.02.09.xx (continued)
ResolutionDescriptionIdentifier
authentication is completed, the authentication
token is not removed from /var/opt/wbem/
localauth file.
created for connections that are
terminated before authentication is
completed.
This defect is fixed in the current release.When upgrading from HP-UX 11i v2 OS to
HP-UX 11i v3 OS, the WBEMServices filesets
QXCR1001071978
and all filesets dependent on WBEM are not
configured correctly in an LDAP environment.
During the configure phase of WBEMServices,
error messages are seen.
With the current fix, cimserverd daemon
monitors the status of both cimserver andThe cimserverd daemon checks if the
cimservermain process is running and restarts
cimserver if cimservermain is not active.
QXCR1001060784 cimservermain processes and restarts
cimserver if either one of the process is
not active.
This defect is fixed in the current release.
With this fix, the wbeminfo.sh script
During previous release, the wbeminfo.sh
script does not display all the registered
QXCR1001064867
is enhanced to display all the registered
providers and the corresponding classes on a
system.
providers and the corresponding classes
on a system.
Defects fixed in A.02.09.04
This defect has been fixed such that the
IndicationTime property displays the
accurate local time.
The IndicationTime property of the
HP_AlertIndication class does not display
the Coordinated Universal Time (UTC). The
QXCR1001017205
event time in the indications that are received
do not match with the local time of the system.
Defects fixed in A.02.09.02
This defect has been fixed such that this
memory leak does not occur.
A memory leak occurs in the cimprovagt
process when the loaded provider reaches the
QXCR1000962884
value specified for the max_thread_proc
parameter. Also, all subsequent
pthread_create() calls fail.
The HP WBEM Services Release Notes
document has been updated with the
The September 2009 version of the HP WBEM
Services Release Notes specified incorrect
QXCR1000984017
correct versions of the SCSI and SAS
provider.
versions of the SCSI provider and SAS
provider.
Defects fixed in A.02.09
This defect has been fixed to resolve this
error message.
In the Networking page of HP System
Management Homepage, the following error
is displayed:
QXCR1000890091
CIM_ERR_FAILED: Error in ioctl()
request SIOCGIFCONF: Invalid
argument
When this error message is displayed, no other
data can be displayed on the Networking
page.
This error is noticed only with HP WBEM
Services versions prior to A.02.09 on HP-UX
11i v1 and v2 systems on which patch
PHNE_35351 and subsequent patches have
been installed.
18 HP WBEM Services Version A.02.09.12 Release Notes