sasmgr.1m (2010 09)

s
sasmgr(1M) sasmgr(1M)
The size of the disk specified should be greater than the size of at least one of the physi-
cal disks in the volume.
If the
-f option is not specified,
sasmgr displays a warning message before continuing
the command. Otherwise, it suppresses the warning message and continues executing
the command. This command requires superuser privileges. Refer to the Security Res-
trictions section below.
bdr The following qualifier must be specified with the
bdr command:
lun Resets the specified target device. This is a destructive operation.
If the
-f option is not specified with this command,
sasmgr displays a warning message
before continuing. Otherwise, it suppresses the warning message and executes the com-
mand.
clear_stat
When the clear_stat command is run without qualifiers, it clears statistics of the SAS I/O
card / HBA represented by device_file .
The following qualifiers are specified with the
clear_stat command:
all Clears all statistics for the SAS I/O card / HBA, all PHYs, all ports, and all targets.
phy Clears statistics for all PHYs or a specific PHY.
phy_in_port
Clears statistics for a port to which the specified PHY belongs to or clears statistics for all
ports.
target
Clears statistics for a specific target or all targets.
delete
One of the following sets of qualifiers must be specified with the delete
command:
raid
raid_vol
This set of qualifiers is used to delete the RAID volume given by the volume ID. The
volume ID can be obtained from the get_info command using the raid qualifier. If a
volume ID of all is specified, then all the RAID volumes will be deleted.
If the
-f option is not specified, sasmgr displays a warning message before continuing
the command. Otherwise, it suppresses the warning message and continues executing
the command. This command requires superuser privileges. Refer to the Security Res-
trictions section below.
raid
spare
This set of qualifiers is used to delete the Core I/O card / HBA spare disk.
If the
-f option is not specified, sasmgr displays a warning message before continuing
the command. Otherwise, it suppresses the warning message and continues executing
the command. This command requires superuser privileges. Refer to the Security Res-
trictions section below.
disable
Disables the SAS I/O card / HBA. This is a destructive operation. The SAS I/O card / HBA
will become offline, all current I/Os will be aborted, and new I/Os will fail. An enable opera-
tion must be performed in order to bring the SAS I/O card / HBA back online.
If the
-f option is not specified with this command, sasmgr displays a warning message
before continuing. Otherwise, it suppresses the warning message and executes the command.
download
The following qualifiers must be specified with the download command:
downloadfile
enc_bay
Updates the firmware on a SAS disk. The command will update disk firmware for regu-
lar physical disks, as well as those that are part of a RAID volume. The downloadfile
qualifier takes the name of the file containing the new disk firmware. The enc_bay
HP-UX 11i Version 3: September 2010 3 Hewlett-Packard Company 3