Realize new workload migration and consolidation possibilities

9
app2 2 4 GB 1 DVD install.iso recovLAN dbLAN
appLAN
mgmtLAN
0
Ignite 1 3 GB 1 - - recovLAN mgmtLAN 0
Spares for
future
growth
6 12 GB 4 - - - - 2
VSP 1 6 GB NA NA 2 disks
(mirrored)
- - mgmtLAN
Review the configuration and verify the new system’s hardware
requirements
While reviewing table 2, you should consider what new server you plan to move to and make sure that:
The resources added for projected growth will actually fit the planned applications
Each vPar has connectivity to all of the required LANs and storage
The resources allocated for the migrating vPars take into account any changed requirements caused by new versions
of the applications
Resources have been allocated for the VSP: at least 1 CPU core, sufficient memory to manage the vPars (~20 percent
of the total vPar memory), local storage for the VSP’s OS, and networking connections
The physical server can actually hold all of the planned resources (It is often a good idea to get a server that can
expand to twice the capacity initially called for)
Install the VSP (server or nPartition) with HP-UX vPars and
Integrity VM 6.1
Start with the HP-UX 11i v3, March 2012 Update Release (or later). If you purchase either the Virtual Server or Data
Center Operating Environments (VSE-OE or DC-OE), then select Integrity vPars and Virtual Machines v 6.1 for installation
at the same time as the OS. Select the bundles BB068AA, VirtualBase, and any patches listed in the Integrity vPars and
Virtual Machines Release Notes (available at hp.com/go/vPars). If you have purchased the Base OE (BOE) or the HA OE,
vPars and Integrity VM version 6.1 is also available as a separately purchased product on the Application Release media.
Refer to the product information available at hp.com/go/vPars for more information. If you are migrating to a
Superdome 2, configure the nPartitions and stay in nPar mode. Do not go into vPar mode. If you are migrating to c-Class
i2 blades, each BladeSystem is a single server and may be administrated in a manner similar to the legacy rackmount
servers once physical installation has been completed. The rx2800 is a single server.
Perform the installation:
Install the HP-UX 11i v3 VSE-OE, explicitly selecting BB068AA and VirtualBase. Refer to the HP-UX 11i v3 Installation
and Update Guide for the March 2012 Release.
Apply the recommended configuration changes/performance tunes referenced in the Release Notes.
Create vswitches for each of the shared and internal LANs desired. Detailed instructions are available in the HP vPars
and Integrity Virtual Machines Administrator Guide.
Configure DIO, if desired. See the Administrator Guide.
Configure NPIV, in particular, set up the GUIDMGR server if none currently exists, and configure the vPars host to use
it. (See the NPIV white paper at hp.com/go/vPars).