User Guide

If the printer has not been turned on before, or a new EEPROM has been installed, the default values
for the printer functions will be loaded into the EEPROM during startup.
Runtime Diagnostics
Runtime diagnostics (sometimes called level 2 diagnostics) run during normal printer operation. When
the following conditions occur, the printer automatically turns off the appropriate motors and disables
printing to prevent damage to the printer.
Paper out
Rear cover open
Knife unable to home
Printhead too hot
Voltages out of range
The LED on the operator panel will signal when these conditions occur as well as indicate printer
state or mode.
LED Behavior Printer Status
Off No power
Fast blink Firmware download
Fast blink Level 0 diagnostics (occurs at power on, and on
reset); paper out
Slow blink Temperature error or voltage error
Steady on All other issues
Remote Diagnostics
Remote diagnostics (sometimes called level 3 diagnostics) keep track of the following tallies and
prints them on the receipt during the print test. These tallies can be used to determine the printer’s
state of health.
Model number
Serial number
CRC number
Number of lines printed
Number of knife cuts
Number of hours the printer has been on
Number of flash cycles
Number of cutter jams
Diagnostics 17