HP VAN SDN Controller Administrator Guide

42
OpenFlow Trace
This feature provides a trouble-shooting tool for observing (for a very brief period 10 seconds
by default) the OpenFlow interactions captured in messages between the controller and the
network. Included are Open Flow messages received by the controller from the OpenFlow
devices it manages, and all messages sent from the controller to the devices (both the messages
received and the messages sent).
Figure 38 Example of OpenFlow Trace Default Display
Start, Stop, or Clear/Reset Trace
To operate OpenFlow Trace, use the control buttons above the Time field:
Figure 39 Trace Controls
Starts Trace.
Stops Trace (unless already stopped due to configured timeout).
Clear/reset the Trace view.
Change the Trace Interval
The default trace interval is ten seconds. To set a shorter or longer interval:
1. Click on Configurations.
2. Open the com.hp.sdn.ctl.of.impl.TraceManager component.
3. Click on Modify.
4. In the Value field, enter the desired duration in seconds for active trace recording.
5. Click Apply to set the new timespan for active trace reconding, and return to the
OpenFlow Trace view..