HP VAN SDN Controller Administrator Guide

76
A Specifications
Table 6 Single Controller
2.3M
Flows(packets)/Second
2K
Maximum Connected OpenFlow Switches
50K
Connected OpenFlow ports
Table 7 Team of Three Controllers
6.5M
flows(packets)/second
4K
Maximum Connected OpenFlow Devices
Note: Same maximum per-controller as for a standalone controller. Team
members can work in ACTIVE/ACTIVE mode and can control network regions.
OpenFlow switches can be distributed across different regions as required.
50K
Connected OpenFlow Ports
Note
The above measurements were done with the following server configuration set-up.
DL560 16 cores 2693 MHZ 64GB RAM
Results may vary based on the type of server used for the controller, and on the server
configuration.
For measuring flows-per-second, the learn.IP option in
com.hp.sdn.ctl.nodemgr.impl.NodeManager (under Configurations/Component) in the
controller GUI should be set to "false". (The default setting is "true".)
Figure 42 Reset "learn.ip" to "false"
If one controller in a team of three goes down, the team continues to function. If a second
controller goes down, the remaining controller suspends operation and the domain serviced by
the team becomes unmanaged.