HP BladeSystem c-Class Virtual Connect Support Utility Version 1.2.2 Release Notes
General requirements 5
General requirements
• Microsoft® Windows® XP (Service Pack 1 or 2), Windows Server™ 2003, or Windows Vista®
must be installed on the client.
• Users must have Administrative or Power User privileges on the client system to install and run the
utility.
• A valid HP Virtual Connect firmware package must be available to install. The firmware can be
downloaded from the HP website (http://www.hp.com
). Click Software and Driver Downloads, and
then search for "Virtual Connect Firmware."
• No FTP servers can be running on the client system. A port conflict can prevent the utility from
performing an update.
• If Virtual Connect firmware version 1.20 or higher is already installed on the primary VC-Enet
module, HP recommends using the Virtual Connect Manager embedded firmware update
capabilities to upgrade the firmware to v1.20 or higher.
• Do not close the console application when a firmware update is in progress. If the application is
closed before the update completes, the module firmware might not update properly, causing the
module firmware to be inoperative.
• An Onboard Administrator user account with Administrative privileges and access to all interconnect
bays must be available for use. If the enclosure is currently imported into a Virtual Connect domain,
a Virtual Connect user account with Domain privileges is also required.
• The user must have Ethernet network connectivity between the client system and the enclosure
Onboard Administrator. To validate this connectivity, open a web browser to the enclosure Onboard
Administrator before running the utility.
• The user must have Ethernet network connectivity between the client system and the interconnect
modules in the enclosure.
• No firewalls can exist between the client system and the remote enclosure Onboard Administrator. If
a firewall exists, and is blocking ports, then the utility can not open a connection with the remote
modules to perform the update.
• Onboard Administrator firmware 1.30 or higher is required on the target enclosure. OA firmware
version 2.10 is recommended.
• Only one instance of the VC Support Utility can be run at a time on a single client.
• During firmware update operations, the modules are unavailable for use. Any attempt to reset or
remove the modules during the update process could result in a corrupted firmware image. In
addition, do not reset the Onboard Administrator of the target enclosure or update its firmware while
VC modules are being updated. Doing so can interfere with the firmware update process and cause
it to fail. During the firmware update process, connectivity through the modules, which might be
hosted to servers in the enclosure, can be interrupted temporarily.
• During a firmware update session, only use a single client to update modules in a specific remote
enclosure. Using multiple clients to interface to the same enclosure remotely can interrupt the
firmware update process and prevent it from completing successfully.