HP BladeSystem c-Class Virtual Connect Support Utility Version 1.5.2 Release Notes
General requirements 7
• Only one instance of the VC Support Utility accessing a single enclosure can be run on a single client
at one time.
• During firmware update operations, the modules are unavailable for use. Any attempt to reset or
remove the modules during the update process could result in a corrupted firmware image. In addition,
do not reset the Onboard Administrator of the target enclosure or update its firmware while VC modules
are being updated. Doing so can interfere with the firmware update process and cause it to fail. During
the firmware update process, connectivity through the modules, which might be hosted to servers in the
enclosure, can be interrupted temporarily.
• During a firmware update session, only use a single client to update modules in a specific remote
enclosure. Using multiple clients to interface remotely with the same enclosure can interrupt the firmware
update process and prevent it from completing successfully.
• If the firmware update client is interrupted or loses network connectivity during the update, reset the
affected module and restart the firmware update process.
• VCSU supports only IPv4 addresses. IPv6 support is not yet available.
• In a multi-enclosure environment, the Onboard Administrator username and password must be identical
across the local and all remote enclosures in the Virtual Connect domain. Otherwise, firmware update
of the remote enclosures does not succeed.