HP Virtual Connect 3.60 Release Notes
Languages 5
Languages
Languages supported for this release: English, Japanese
Enhancements
Version 3.60 of Virtual Connect contains support for the following products:
• HP ProLiant BL420c Gen8 Server Series
• HP ProLiant BL465c Gen8 Server Blade
• HP LPe1205A 8Gb FC HBA for BladeSystem c-Class
• HP Ethernet 1Gb 2-port 361FLB Adapter
• HP Ethernet 1Gb 4-port 366M Adapter
Fixes
The following issues have been resolved in the VC 3.60 release:
• Resolved an issue where the restore domain operation would fail if any of the storage blades were in
a power-on state.
• Resolved an issue with concurrent hot-plug servers that could leave a server disconnected from assigned
networks. This issue applied to servers with Flex-10 or Flex-Fabric ports with assigned profiles.
• Resolved an issue observed on multi-blade servers with a multi-port mezzanine card where HP-UX had
an extended boot time and the EFI driver did not attach to the multi-port mezzanine card. This happened
when a multi-port mezzanine card had only a single Ethernet connection assigned to a port and the
other ports did not have connections assigned.
• Resolved an issue with the HP VC 1/10Gb-F module when using mixed media types (RJ45 and SFP) in
an LACP channel, where when the VC module was reset, the channels using SFP did not rejoin either
channel.
• Previously, to enable SMIS you also had to enable SNMP. Now SNMP and SMIS can be independently
enabled.
• Resolved an issue where the downlinks from some HP servers were shut down by SmartLink during a
firmware upgrade.
• Resolved an issue where the CLI did not block restoring a configuration when any of the servers were
still powered on.
• Resolved an issue where the VCM GUI did not allow '@' and '#' as part of a VCM user password, but
the VCM CLI did not have these restrictions.