Resolved issues 16
Resolved issues
The following issues that existed in Virtual Connect v1.16 have been resolved in Virtual Connect v1.20:
The Virtual Connect Manager now recovers from a dual-OA failover or the replacement of a single
OA without requiring a reset of the Virtual Connect Manager.
Under certain fail-over conditions a loop could be caused for a very short window (up to about 120
mS). This time was sufficient for BPDUs to slip through and BPDUguard to run.
VC-FC Port operational and speed statuses reflected configuration settings rather than actual port
status information.
VC-FC module no longer presents "Link to Management URL" in the OA graphical interface because
web-based management is not available.
VC-FC module now supports SNMP and SMI-S management interfaces in read-only mode.
VC-FC corrected an issue with Non-Disruptive Code Load and Activation when all 16 server blades
where logged in to the Fibre Channel SAN.
If non-Administrator credentials were entered for the Onboard Administrator during Virtual Connect
Domain Import, the import failed without explanation.