HP Virtual Connect 4.10 Release Notes

Prerequisites 8
reset server command. The problem can also be resolved if VC restarts, fails over, reboots,
receives a firmware update, or re-evaluates the server after an OA failover.
Issue
Under certain circumstances, the checkpoint status icon in the GUI persists for a long time and is not cleared.
The CLI also shows a "Checkpoint Status: Invalid" status in the show domain command output. This
condition occurs periodically after a VCSU firmware upgrade of the VC module firmware.
Workaround
To resolve this issue, reset VCM on the primary module or reset the primary module using the OA.
Prerequisites
VC SR-IOV prerequisites:
o Supports the following adapters:
HP Flex-10 10Gb 2-port 530FLB Adapter
HP FlexFabric 10Gb 2-port 534FLB Adapter
HP Flex-10 10Gb 2-port 530M Adapter
HP FlexFabric 10Gb 2-port 534M Adapter
HP NC552m Flex-10 Adapter
HP NC553m 10Gb 2-P FlexFabric Converged Network Adapter
HP FlexFabric 10Gb 2-port 554M Adapter
HP Flex-10 10Gb 2-port 552M Adapter
HP FlexFabric 10Gb 2-port 554FLB Adapter
o Supports the following operating systems:
Windows 2012 (64-bit)
VMware ESXi 5.1 (64-bit), Does not support adapters 534FLB and 534M.
RHEL 5.8, 5.9 (64-bit with KVM)
RHEL 6.2, 6.3 (64-bit with KVM)
SLES 11 SP2, SP3 (64-bit with KVM)
The lowest VCEM 7.2.2 support compatibility mode is set to VC 3.30.
If you are planning to use VC 4.10 firmware in a VCEM environment, HP recommends upgrading to
VCEM v7.2.2. For more information about the VC firmware that is compatible with VCEM, see the
Virtual Connect Enterprise Manager User Guide on the HP website
(http://h20000.www2.hp.com/bizsupport/TechSupport/DocumentIndex.jsp?contentType=Support
Manual&lang=en&cc=us&docIndexId=64179&taskId=101&prodTypeId=18964&prodSeriesId=360
1866).
Customers using Insight Control for VMware vCenter Server should upgrade to version 6.3 when using
Virtual Connect firmware version 3.30 and later. Version 6.3 fixes a known issue with version 6.2
where Virtual Connect data did not display correctly.