HP Virtual Connect Fibre Channel Networking Scenarios Cookbook
124
Verification of the SAN Fabrics configuration
Make sure all of the SAN fabrics belonging to the same Bay are connected to the same core FC SAN fabric switch:
1. Go to the SAN Fabrics screen.
2. The Connected To column displays the upstream SAN fabric switch to which the VC module uplink ports are
connected. Verify that the entries from the same Bay number are all the same, indicating a single SAN fabric.
For additional verification and troubleshooting steps, see Appendix F.
Blade Server configuration
See Appendix B for server profile configuration steps with VC FlexFabric.
Summary
This VC FlexFabric-20/40 F8 scenario shows how you can create multiple VC SAN fabrics that are all connected to the
same redundant SAN fabric. This configuration enables you to control the throughput for a particular application or
set of blades.
Same upstream fabric