HP Virtual Connect Fibre Channel Networking Scenarios Cookbook

24
In order to give more granular control over which server blades use each uplink port, several Direct-Attach VC SAN
fabrics can be connected to the same 3PAR storage System. This configuration can enable the distribution of servers
according to their I/O workloads.
Figure 21: Multiple Direct-Attach VC SAN Fabrics connected to the same 3PAR array
VC Domain
VC SAN A-1
VC Direct-Attach SAN Fabrics
defined in the VC Domain
Direct attached
Storage System
VC Domain
VC SAN B-1
Bay 1
Bay 2
3PAR Storage
System
VC FlexFabric Module VC FlexFabric Module
VC SAN A-2 VC SAN B-2
Up to four HP 3PAR Storage Systems can be directly connected to a redundant pair of VC FlexFabric modules; this is
because only 4 uplink ports are available for FC connection on the FlexFabric module.
Figure 22: Maximum 3PAR arrays connected to a VC Domain
VC Direct-Attach SAN Fabrics
defined in the VC Domain
Direct attached
Storage Systems
3PAR Storage
Systems
VC Domain
VC SAN A-1
VC SAN B-1
Bay 1
Bay 2
VC FlexFabric Module VC FlexFabric Module
VC Domain