HP Virtual Connect for c-Class BladeSystem Version 2.30 User Guide

Hardware information screens 153
If these conditions are not met, the Remove from Domain button is not available, or an error message
appears.
If a VC-Enet module is restarted from a power-cycle or reboot, or the module is removed and inserted, a
link might not be re-established between the module and the ports of an NC364m mezzanine card. If the
server is rebooted, the link is established on all ports on both sides of the connection. Manually toggling
the link from the server should also restore the link.
Interconnect Bay Overall Status icon definitions
Icon Operational state Meaning Corrective action
OK Device is fully operational. None
Unknown Device operational state cannot
be determined.
Check Onboard Administrator
communication.
(blue)
Initializing Device is initializing. Wait until initialization is complete.
(This icon should only be seen at
startup.)
(yellow
)
Degraded Device is partially operational,
but capability is lost.
Check and correct the Onboard
Administrator error condition.
(orang
e)
Misconfigured Device has a configuration error. Correct the Virtual Connect Manager
configuration attributes.
(orang
e)
Incompatible Device does not match the
configuration.
Remove the incorrect hardware.
Insert the correct module.
(orang
e)
No communication Cannot communicate with the
device.
Check the physical connections and
IP address.
Missing Device is configured but not
accessible.
Insert the correct hardware module.
Failed Device is not operational because
of an error.
Reset the device or application, or
replace the device.
Interconnect Bay OA Reported Status icon definitions
Icon Operational state Meaning Corrective action
OK Device is fully operational. None
Unknown Device operational state cannot
be determined.
Check Onboard Administrator
communication.
(yellow
)
Degraded Device is partially operational,
but capacity is lost.
Check and correct the Onboard
Administrator error condition.
Failed Device is not operational because
of an error.
Check and correct the Onboard
Administrator error condition.