HP Virtual Connect Manager Command Line Interface for c-Class BladeSystem Version 3.10/3.15 User Guide

Command line 37
Item Description
show igmp
Display Ethernet IGMP Snooping settings.
Syntax
show igmp
Example
->show igmp
Displays IGMP Snooping settings
interconnect
Manage I/O interconnect modules.
Supported actions: help, remove, show
Item Description
remove interconnect
Remove an interconnect module from the domain. Normally this command is
used if a module has been physically removed from the enclosure. To be
removed, the module must not be currently in use by any element in the domain.
Syntax
remove interconnect <ModuleID|*>
Parameter
ModuleID(required)
The ID of the module to remove. The ID format is
<EnclosureID>:<BayNumber>. To display a list of the IDs corresponding to
modules in the domain, use the
show interconnect
command.
Examples
->remove interconnect enc0:2
Removes a specific interconnect module (bay 2) from the domain
->remove interconnect *
Removes all interconnect modules from the domain that are not present physically
in any enclosure
->remove interconnect enc0:*
Removes all interconnect modules that are not physically present in a specific
enclosure
->remove interconnect *:2
Removes interconnect modules (bay 2) from the domain that are not physically
present in all enclosures
Item Description
show interconnect
Display all interconnect modules known to exist in the domain.
Syntax
show interconnect [<ModuleID>|*]
Parameter
ModuleID (optional)
The ID of the interconnect module. “*” displays detailed view of all the modules
in the VC domain. If not specified, a summary output of all the modules appears.
Examples
->show interconnect
Displays a summary listing of all interconnect modules
->show interconnect *
Displays detailed information for all interconnect modules
->show interconnect *:5
Displays detailed information for all enclosures with interconnect modules in