HP BladeSystem c-Class Virtual Connect Support Utility Version 1.5.1 User Guide

Commands 12
On an enclosure configured for Virtual Connect, the command displays the following:
Onboard Administrator firmware version
Power: On, Off, other
Health: OK, Degraded, Failed, other
IP Address
Connectivity Test
For VC-Enet Modules:
o VCM Mode: Primary, Backup, Subordinate, Unintegrated
o Module Configuration: In Sync, Not In Sync, Invalid
o Domain Configuration (for primary or backup VC-Enet modules): In Sync, Not In Sync
The primary Virtual Connect manager saves the domain configuration data to the backup module in a VC
domain at a regular interval. The 'Domain configuration' state indicates whether or not this data is in sync
between the two modules.
The 'Module configuration' state indicates whether all the modules in an enclosure are in sync with the
primary module regarding the Virtual Connect configuration information.
If a module is being reconfigured by Virtual Connect, or is rebooting, a 'Not In Sync' or 'Invalid'
configuration status might appear. Wait up to 2 minutes, and then execute the healthcheck command
again.
Item Description
Syntax
vcsu -a healthcheck -i <IP> -u <USER> -p <PWD>
Parameters:
IP
IP address of the active OA in the enclosure*
USER
Name of the OA user with privileges to access all enclosure interconnect bays. Minimum
length is 3 characters.
PWD
Password of the OA user. Minimum length is 3 characters.
*In a multi-enclosure environment, this must be the IP address of the active OA in the primary enclosure.
Example
List the state of modules in an enclosure:
vcsu -a healthcheck -i 192.168.0.100 -u Administrator -p password
packageinfo
Extract the package information from the supplied package path and display the following information:
Digital Signature Validation (for Virtual Connect firmware version 2.30 and higher)
Package Version
Ethernet Firmware Version Timestamp
Ethernet Firmware Supported Hardware
FC Firmware Version
FC Firmware Supported Hardware