HP BladeSystem c-Class Virtual Connect Support Utility Version 1.5.1 User Guide

Commands 14
Item Description
Syntax
vcsu -a resetvcm -i <IP> -u <USER> -p <PWD>
Parameters:
IP
IP address of the active OA in the enclosure*
USER
Name of the OA user with privileges to access all enclosure interconnect bays. Minimum
length is 3 characters.
PWD
Password of the OA user. Minimum length is 3 characters.
*In a multi-enclosure environment, this must be the IP address of the active OA in the primary enclosure.
Example
Reset a single module in an enclosure:
vcsu -a resetvcm -i 192.168.0.100 -u Administrator -p password -b 1
supportdump
Log into VC Manager using the supplied credentials and access Virtual Connect to request a support
information (debug dump) download. VCSU saves that file in the current directory as the file name
supplied by Virtual Connect. A functioning VC Manager domain is required for this action.
Item Description
Syntax
vcsu -a supportdump -i <IP> -u <USER> -p <PWD> -vcu <VCM USER> -
Parameters:
IP
IP address of the active OA in the enclosure*
USER
Name of the OA user with privileges to access all enclosure interconnect bays. Minimum
length is 3 characters.
PWD
Password of the OA user. Minimum length is 3 characters.
VCM USER
Name of Virtual Connect user with Domain privileges. Required if an enclosure is in a Virtual
Connect domain. Minimum length is 3 characters.
VCM PASS
Password for the Virtual Connect user. Minimum length is 3 characters.
LOCATION
Full path, including file name, to save the support dump file. If not provided, VCSU saves the
support dump file to the file name that VCM provides and downloads it to the current
directory.
*In a multi-enclosure environment, this must be the IP address of the active OA in the primary enclosure.
Example
Save support information:
vcsu -a supportdump -i 192.168.0.100 -u Administrator -p password -vcu
Administrator -vcp password
update
Update the firmware.
The user must provide the primary OA IP address, user credentials, and the package file to use for the
update. The user can also provide an optional bay number.