HP BladeSystem c-Class Virtual Connect Support Utility Version 1.5.2 User Guide
Introduction  8 
Interactive mode question/request  Description  Reference 
for previous question. Enter a 
command. 
-a <command>
Please enter Onboard 
Administrator IP Address: 
(required for all commands except 
discover and packageinfo) IPv4 
address of the active OA in the 
primary enclosure 
Commands (on page 10) 
-i <IP>
Please enter Onboard 
Administrator Username: 
(required for all commands except 
discover and packageinfo) User 
name of the active OA in the primary 
enclosure 
Commands (on page 10) 
-u <USER>
Please enter Onboard 
Administrator Password: 
(required for all commands except 
discover and packageinfo) 
Password of the active OA in the 
primary enclosure 
Commands (on page 10) 
-p <PWD>
Please enter starting IP 
address:
(required) First IP address in the range 
to search 
discover (on page 11) 
-s <START IP>
Please enter ending address: 
(required) Ending IP address in the 
range to search 
discover (on page 11) 
-s <END IP>
Please enter firmware package 
location: 
(required) Full path to the Virtual 
Connect package on the local 
computer 
packageinfo (on page 12) 
report 
update 
-l <FILE>
Please enter Bay Number: 
(optional) Bay number of the target 
module. If not specified, the default is 
all supported modules. 
report 
resetvcm 
update 
version 
-b <BAY>
Please enter the file location: 
(optional) Full path to the 
configuration backup or support dump 
file 
configbackup 
supportdump 
-l <FILE>
Please enter the Configuration 
backup password: 
(optional) Password for the 
configuration backup file 
configbackup 
update 
-cp <CONFIG PASS>
Do you want to force an update 
on modules? (yes/no): 
(optional) Enter Yes to force an update 
on modules. 
update 
-f <FORCE>
Please enter Force Update 
options (eg: version,health): 
Required only if previous question was 
answered yes. Enter options 
separated by a comma. 
update 
-f <FORCE>
Do you want to specify VC-
Enet 
module activation order? 
(yes/no):
(optional) Specify VC-Enet module 
activation order 
update 
-oe <ORDER> 
Please enter VC-Enet module 
activation order (eg: parallel 
or odd-even or serial or 
manual): 
Required only if previous question was 
answered yes. Enter one of the 
following: parallel, odd-even, serial, 
or manual 
update 
-oe <ORDER> 
Do you want to specify VC-FC 
module activation order? 
(yes/no):
(optional) Specify VC-FC module 
activation order. 
update 
-of <ORDER>
Please enter VC-FC module 
Required only if previous question was  update 