HP BladeSystem c-Class Virtual Connect Support Utility Version 1.6.0 User Guide
Commands  11 
discover 
Locate remote OA enclosures that exist on the network within a specified address range. VCSU displays the 
following: 
•  Number of enclosures found 
•  List of enclosure OA IPs with enclosure type, primary OA IP, and VC domain name 
This command is useful if an Administrator cannot remember the exact IP address of the OA on a certain 
enclosure, but knows the general IP address range. 
Item  Description 
Syntax 
vcsu -a discover -s <START IP> -e <END IP> 
Parameters:  
START IP
First IP address in the range to search 
END IP
Last IP address in the range to search 
Example 
Discover an enclosure in a certain address range: 
vcsu -a discover -s 192.168.1.100 -e 192.168.1.200 
configbackup 
Using the supplied credentials, log into VC Manager and access Virtual Connect to request a configuration 
download. VCSU saves that backup in the current directory as the file name supplied by Virtual Connect. A 
functioning VC Manager domain is required for this action. 
Item  Description 
Syntax 
vcsu -a configbackup -i <IP> -u <USER> -p <PWD> -vcu <VCM USER> -vcp 
<VCM PASS> [-cp <CONFIG PASS>] -l <LOCATION>
Parameters:  
IP
IPv4 address of the active OA in the enclosure* 
USER 
Name of the OA user with privileges to access all enclosure interconnect bays. Minimum length 
is 1 character. Maximum length is 40 characters.** 
PWD 
Password of the OA user. Minimum length is 3 characters. Maximum length is 40 
characters.** 
VCM USER 
Name of the Virtual Connect user with Domain privileges. Required if an enclosure is in a 
Virtual Connect domain. Minimum length is 1 character. Maximum length is 31 characters. 
VCM PASS 
Password for the Virtual Connect user. Minimum length is 3 characters. Maximum length is 31 
characters. 
CONFIG PASS 
Optional. Password for the configuration backup file. Supported only for VCM versions 3.00 
and higher. The default is no password. 
LOCATION 
Full path, including file name, to save the configuration backup file. If not provided, VCSU 
saves the configuration backup file to the file name that VCM provides and downloads it to the 
current directory. 
*In a multi-enclosure environment, this must be the IP address of the active OA in the primary enclosure. 
**In a multi-enclosure environment, USER and PWD parameters for the Onboard Administrator must be identical across 
local and all remote enclosures in the Virtual Connect domain. 
Example 