HP BladeSystem c-Class Virtual Connect Support Utility Version 1.6.0 User Guide
Troubleshooting  18 
Troubleshooting 
Error messages 
Error message  Resolution 
This version of the application does not support the 
target enclosure 
Specify a supported enclosure type. 
Unable to get enclosure part number 
Check connectivity with the OA, and then restart the update 
process. 
Another instance of this application is running. 
Please wait until all other instances are completed 
and try again. 
More than one instance of the update utility is attempting to 
run on the client. Wait until all other instances are complete, 
and then try again. 
Unable to initialize Onboard Administrator 
interface 
Check connectivity with the OA, and then restart the update 
process. 
Unable to login to the Onboard Administrator. 
Please confirm the OA IP address and user 
credentials. 
Confirm the OA IP address and user credentials. 
Invalid option 
An invalid option has been specified by the user. Verify the 
list of available options for that command. 
Invalid -a option 
An invalid -a format has been specified by the user. Verify 
the list of available commands. 
One or more parameters missing 
One or more required parameters was not specified. See 
the required syntax for the command. 
Missing -l option 
Specify the required package location. 
Invalid -f option 
The -f version option can only be used with the update 
command. Be sure a valid -f option is specified. 
Invalid OA IP address 
Provide a valid IP address in the proper format. 
Unable to communicate with OA IP 
aaa.bbb.ccc.ddd 
Check connectivity with the OA and verify that you are 
using a valid IP address. 
OA username is longer than 40 characters 
Enter a valid OA username. 
OA user password is greater than 40 characters 
Enter a valid OA user password. 
Invalid bay number 
Specify a valid bay number for the target enclosure. 
OA firmware version a.bb is not supported 
Update the firmware on the target enclosure. 
Unable to communicate with Onboard 
Administrator. Please confirm validity of the OA IP 
address and user credentials. 
Confirm the validity of the OA IP address and user 
credentials. 
Specified Onboard Administrator is not primary 
Specify the OA IP address of the primary OA in the target 
enclosure. 
Unable to get enclosure VC mode information 
Log into VC Manager GUI and resolve any errors with VC 
Manager. Reset the OA to factory defaults, and then log 
into the VC Manager GUI. 
Initialization process failed. Firmware update 
cannot continue. 
Check update requirements, and then try the update again. 