Overview 
This feature enables you to downgrade to a previously installed and running version of VC. 
The following requirements are for downgrading firmware on a VC domain without destroying the domain. 
Otherwise, to downgrade firmware on VC modules, you must first delete the domain and then use the -a 
update command. 
Restrictions 
The following restrictions apply: 
•  You must be running VC version 3.70 or higher to perform a downgrade. 
•  You cannot downgrade to a VC version lower than version 3.17. 
•  A previous upgrade must have been performed on the configuration using VCSU 1.7.0 or higher. 
•  All servers in the domain must be powered off. 
•  Multiple, consecutive firmware downgrades are not allowed. 
•  You can downgrade only to the version previously installed and running on the primary module. 
•  The VC configuration, including physical connections, uplink port connections, and module positions in 
the enclosure, must be identical to the target downgrade configuration. 
•  The VC credentials must be the same before and after the downgrade. After the downgrade, you cannot 
change the password for the account used to perform the downgrade. 