HP BladeSystem c-Class Virtual Connect Support Utility Version 1.9.1 User Guide
Troubleshooting  23 
Error code  Details 
VCSU_ERROR_FTP_NOT_READY 
The FTP server is not ready. 
VCSU_ERROR_FTP_USERNAME_NOT_VALID 
The FTP username is not valid. 
VCSU_ERROR_FTP_PASSWORD_INVALID 
The FTP password is not valid. 
VCSU_ERROR_FTP_REJECTED_PASSIVE_MODE 
The FTP server rejected passive mode. 
VCSU_ERROR_FTP_REJECTED_COMMAND 
The FTP server rejected the command. 
VCSU_ERROR_FTP_NO_RESPONSE 
The FTP server is not responding. 
VCSU_ERROR_FTP_RECEIVE_ERROR 
An FTP receive error exists. 
VCSU_ERROR_FTP_INVALID_IP 
Invalid FTP server IP address 
VCSU_ERROR_NO_UPDATABLE_MODULES 
No target modules are found that can be 
updated. 
VCSU_ERROR_MODULE_UPDATE_NOT_REQD 
The specified module is not required to be 
updated. 
VCSU_ERROR_MODULE_ACTIVATE_NOT_REQD 
The specified module is not required to be 
activated. 
VCSU_ERROR_MODULE_INFO_NOT_AVAILABLE 
The specified module's information is not 
available. 
VCSU_ERROR_MODULE_NOT_PRESENT 
The specified module is not present. 
VCSU_ERROR_MODULE_NOT_POWERED_ON 
The specified module is not powered on. 
VCSU_ERROR_MODULE_NOT_OPERATIONAL 
The specified module is not operational. 
VCSU_ERROR_ADMIN_PERMISSIONS_REQD 
The admin privileges are required to upgrade 
specified modules. 
VCSU_ERROR_CHECKPOINT_RENAME_FAILED 
The checkpoint rename operation failed on the 
specified modules. 
VCSU_ERROR_VCM_CONFIGURATION_NOT_IN_SYNC 
The VC configuration is still not in sync. 
VCSU_ERROR_VCM_FAILOVER_FAILED 
Failover to backup module failed. 
VCSU_ERROR_BAY_CONFIGURATION_FAILED 
Unable to configure the bay 
VCSU_ERROR_CLI_COMMAND_EXECUTION_FAILED 
Unable to execute CLI command on the target 
module 
VCSU_ERROR_MODULE_NOT_UPGRADABLE 
The specified module is not upgradeable. 
VCSU_ERROR_MODULE_COMMAND_FAILED 
The command on the target module failed. 
VCSU_ERROR_RESET_TIME_OUT 
The reset on the target module timed out. 
VCSU_ERROR_RESET_FAILED 
The reset on the target module failed. 
VCSU_ERROR_INVALID_MODULEID 
The specified module ID is invalid. 
VCSU_ERROR_PREVIOUS_UPDATE_NOT_COMPLETETD 
A previous firmware update operation on one 
or more modules is not complete. 
VCSU_ERROR_MULTIPLE_INSTANCE 
Another firmware update is running against the 
specified OA. 
VCSU_ERROR_FC2_FW_EXTRACTION_FAILED 
The extraction of the VC FC2 firmware package 
failed. 
VCSU_ERROR_DOWNGRADE_FROM_MULTIENCLOSURE 
A downgrade from a 2.10 multi enclosure 
domain is not supported. 
VCSU_ERROR_NOT_MULTIENCLOSURE 
Invalid module IDs for single enclosure update 
VCSU_ERROR_VCM_MODE_RESTORE_FAILED 
Failed to restore the VC mode of primary or 
backup module 
VCSU_ERROR_ACTIVATION_FAILED 
Failed to activate one or more modules 
VCSU_ERROR_UNINITIALIZED_MUTEX 
Invalid mutex found 