HP Virtual Connect 3.60 Release Notes
Languages  5 
Languages 
Languages supported for this release: English, Japanese 
Enhancements 
Version 3.60 of Virtual Connect contains support for the following products: 
•  HP ProLiant BL420c Gen8 Server Series  
•  HP ProLiant BL465c Gen8 Server Blade  
•  HP LPe1205A 8Gb FC HBA for BladeSystem c-Class  
•  HP Ethernet 1Gb 2-port 361FLB Adapter  
•  HP Ethernet 1Gb 4-port 366M Adapter  
Fixes 
The following issues have been resolved in the VC 3.60 release: 
•  Resolved an issue where the restore domain operation would fail if any of the storage blades were in 
a power-on state. 
•  Resolved an issue with concurrent hot-plug servers that could leave a server disconnected from assigned 
networks. This issue applied to servers with Flex-10 or Flex-Fabric ports with assigned profiles. 
•  Resolved an issue observed on multi-blade servers with a multi-port mezzanine card where HP-UX had 
an extended boot time and the EFI driver did not attach to the multi-port mezzanine card. This happened 
when a multi-port mezzanine card had only a single Ethernet connection assigned to a port and the 
other ports did not have connections assigned. 
•  Resolved an issue with the HP VC 1/10Gb-F module when using mixed media types (RJ45 and SFP) in 
an LACP channel, where when the VC module was reset, the channels using SFP did not rejoin either 
channel. 
•  Previously, to enable SMIS you also had to enable SNMP. Now SNMP and SMIS can be independently 
enabled. 
•  Resolved an issue where the downlinks from some HP servers were shut down by SmartLink during a 
firmware upgrade. 
•  Resolved an issue where the CLI did not block restoring a configuration when any of the servers were 
still powered on. 
•  Resolved an issue where the VCM GUI did not allow '@' and '#' as part of a VCM user password, but 
the VCM CLI did not have these restrictions. 