HP Virtual Connect 4.01 Release Notes

Issues and workarounds 7
HP Systems Insight Manager might incorrectly identify the HP VC 8Gb 24-Port FC Module as a SAN
switch due to the incorrect value returned in the SysObjectOid.
The timestamp for SNMP traps from VC-FC interconnect modules is now in sync with the timestamp kept
by Virtual Connect Manager.
An error message: "The operation resulted in the following error null" appeared when trying to copy a
working profile with multiple networks that belong to a user-defined network access group.
HP VC 8Gb 20-port FC modules could not operate at 8Gb reliably when connecting to Cisco Nexus
5xxx series switches.
The "Go to Network" action on the Ethernet Networks (Server Connections) screen did not open the Edit
Network screen.
The Virtual Connect Manager CLI did not allow modification of an already existing Ethernet profile
connection with an index of 100 or higher.
An extra button appeared when using Internet Explorer 8 to view the Detailed Statistics screen for FC
uplink ports on a VC FlexFabric module. If this button was clicked, and then the Back to Previous Page
button was clicked, it changed the tabs in the main window. The extra button is removed.
DCC stayed unavailable after server power on and online speed changes failed.
VCM CLI parameters passed to commands were not being enclosed by quotes, and any quotes
embedded in the data should also be protected by an escape character.
The Name-server had the wrong portID and WWN displayed. This issue usually occurred when power
cycling all servers in an enclosure at the same time.
Resolved an issue caused by enabling the "Prevent flooding of unregistered multicast traffic" option
when using VCEM to manage the VC domain with the "VCEM Compatibility Mode" set to a VC
firmware version earlier than 3.70.
Issues and workarounds
Issue
The Domain Setup Wizard does not allow changes to the Advanced User Settings to be saved. The settings
can be updated, but when you click Next, the changes are not saved and no error message is displayed.
These settings include: Require Strong Passwords, Minimum Password Length, Primary Login Method, and
Session Timeout.
Workaround
Go to the Local Users page on the Virtual Connect Home Page, where the settings can be changed and
saved.
Issue
Virtual Connect supports a combined total of 128 private and FCoE networks. Creating either private or
FCoE networks in excess of this limit might result in the misconfiguration of the network being added.
Issue
On VC 8Gb 24-Port FC Module uplink failover, the first FLOGI is dropped due to the N-port being set to 255.