HP Virtual Connect Fibre Channel Networking Scenarios Cookbook

144
4. To verify that NPIV is enabled on a specific port, enter following command for port ext1:
CiscoSANswitch# show flogi database interface ext1
In the PORT NAME column, more than one HBA appears. This indicates a successful implementation of VC-FC.
On the enclosure, two server blade HBAs are installed and powered on, and either an HBA driver is loaded or the
HBA BIOS utility is active. The third WWN on the port is the VC module (currently, all VC-FC modules use the
20:00…range).
5. If the VC module is the only device on the port, verify that:
- A VC profile is applied to at least one server blade.
- At least one server blade with a profile applied is powered on.
- At least one server blade with a profile applied has an HBA driver loaded.
- You are using the latest BIOS version on your HBA.
Port WWN of the VC-FC
Four servers are
currently connected