HP Virtual Connect Fibre Channel Networking Scenarios Cookbook
29
Details about the 3PAR controller connectivity
HP 3PAR Controller Nodes are always installed in pairs, and a system can support from 2 to 8 controllers.
9 PCI-e slots are available per controller node and are used for both host and drive chassis connections using HP
3PAR Host/Disk Adapters.
As a best practice, HP recommends using PCI slots 2, 5, 8, 1, 4, 7 for the Direct-Attach FlexFabric connections.
These PCI slots are also recommended for the host connections.
The 9 PCI-e slots are equally balanced across 3 PCI-e buses so it is better to connect the FlexFabric uplinks from 2
to 7 in the following order: 2 5 8 1 4 7.
If only two HP 3PAR Host adapters are available, the connections should be load balanced across the two
adapters.
The remote copy port (port E1) used with a Direct-Attach 3PAR configuration is also seen in Figure 28.
Figure 30: HP 3PAR V-Class controller node recommended connection
3PAR StoreServ 10000
Controller Node
Remote Copy Ethernet 1Gb port (RCIP)
PCI Slots
recommended for
Virtual Connect
FlexFabric Connections
6 7 8
3 4 5
0
1 2
E1
0
1
Controller Node 0
and
Controller Node 1
c-class enclosures
Recommended connection order : slot 2 5 8 1 4 7
2 5 8
1
4
7
HP 3PAR StoreServ 10400
Note: This diagram shows only the first controller connections.