HP Virtual Connect for c-Class BladeSystem Setup and Installation Guide
Component identification  100 
Item  LED description  Status 
8 
X7/X8 port status  Green = Port is configured and operating as 
an uplink port connected to a data center 
fabric. 
Amber = Port is operating as a stacking link 
interconnecting Virtual Connect modules. 
Blue = Port locator (PID) 
Off = Unconfigured 
9 
X1/X6 port status  Green = Port is configured and operating as 
an uplink port connected to a data center 
fabric. 
Amber = Port is operating as a stacking link 
interconnecting Virtual Connect modules. 
Blue = Port locator (PID) 
Off = Unconfigured 
10 
X1 shared port 
activity 
Green = Port is active. 
Off = Port is inactive. 
Shared port operation 
Port X1 (10BASE-CX4) and Port X1 (SFP+) 
Port X1 (10BASE-CX4) is multiplexed with Port X1 (SFP+). Either the CX-4 port is active or the SFP+ port is 
active, but not both. The triangle LED underneath each port indicates which port is active. The SFP+ port 
always has precedence over the CX4 port. 
•  If there is a module installed in the SFP+ port, the SFP+ port is the active port. 
o  The LED under the SFP+ port is on. 
o  The LED under the CX4 port is off. 
•  If there is no module installed in the SFP+ port, the CX4 port is the active port. 
o  The LED under the CX4 port is on. 
o  The LED under the SFP+ port is off. 
Port X7 and   port X8 
•  Port X7 (SFP+) and port X8 (SFP+) are each multiplexed with an internal 10Gb interface cross-link, 
which is provided on the enclosure midplane between two horizontally adjacent VC modules to 
establish stacking links. Either the port is active or the internal cross-link is active, but not both. The 
triangle LEDs underneath ports X7 and X8 indicate whether the SFP+ port is active or the internal 
cross-link is active. The SFP+ port always has precedence over the internal cross-link port. Port X7 is 
shared with internal cross-link 1, and Port X8 is shared with internal cross-link 2.  
•  If there is a module installed in the SFP+ port, the SFP+ port is the active port. 
The LED under the SFP+ port is on. 
•  If there is no module installed in the SFP+ port, and the port has not been configured as an uplink in a 
VC Ethernet network, then the corresponding internal cross-link is the active port. 
The LED under the SFP+ port is off. 
•  If there is no module installed in the SFP+ port, and the port has been configured as an uplink in a VC 
Ethernet network, then the SFP+ port is the active port. 
The LED under the SFP+ port is on. 