HP Virtual Connect for c-Class BladeSystem Setup and Installation Guide
Installation  31 
2. 
Prepare the VC-Enet module for installation (HP VC Flex-10 10Gb Ethernet Module shown). 
3.  Install the module into the interconnect bay (HP VC Flex-10 10Gb Ethernet Module shown). Push the 
module in slowly and smoothly until it is firmly seated. 
4.  If the Virtual Connect configuration includes three or more VC-Enet modules, install stacking links 
(typically 10GBASE-CX4 cables) between the modules. For more information, see "Connecting Virtual 
Connect Ethernet Module uplinks (on page 39)." 
5.  Connect the data center network cables to the appropriate VC-Enet module faceplate ports. This step 
can be deferred until after setup of the Virtual Connect Manager software. See "Default module 
configuration (on page 11)." 
For VC-Enet Modules with fiber Ethernet ports (such as 1000BASE-SFP and 10GBASE-XFP), fiber ports 
can be used to connect to the data center if they are populated with a supported pluggable SFP, XFP, 
or SFP+ transceiver module. 
For HP Virtual Connect Flex-10 10Gb Ethernet Modules, the SFP+ ports can be used to connect to the 
data center if they are populated with a supported pluggable SFP or SFP+ transceiver module. 










