HP Virtual Connect for c-Class BladeSystem Setup and Installation Guide

Installation 36
2.
Prepare the VC-FC module for installation (HP Virtual Connect 4Gb Fibre Channel Module shown).
3. Install the VC-FC module into the interconnect bay (HP Virtual Connect 4Gb Fibre Channel Module
shown). Push the module in slowly and smoothly until it is firmly seated.
4. Connect the data center SAN switch ports to the VC-FC module 1/2/4 Gb SFP ports.
IMPORTANT: For proper thermal operation, always install SFP dust covers in SFP ports without
SFP transceivers installed.
IMPORTANT: For proper Virtual Connect operation, always assign an IP address to each server
blade iLO and interconnect module.
5. Review the Onboard Administrator bay summary screens to verify that each server blade iLO and
interconnect module has been assigned an IP address. Each IP address must be valid and unique, and
all iLOs and VC modules must be on the same subnet. For more information, see the HP BladeSystem
Onboard Administrator User Guide on the Installing tab of the HP BladeSystem Technical Resources
website (http://www.hp.com/go/bladesystem/documentation).