HP Virtual Connect for c-Class BladeSystem Setup and Installation Guide
Installation  44 
switchport 
switchport trunk encapsulation dot1q 
switchport trunk allowed vlan 10,20,30,40 
switchport mode trunk 
no ip address 
speed 1000 
channel-protocol lacp 
channel-group 10 mode active 
Failover and check-pointing 
VCM runs as a high-availability pair when VC-Enet modules are installed in horizontally adjacent 
interconnect bays. The active VCM is usually on the lowest odd numbered bay when the enclosure is 
powered up. 
Each time a configuration is changed, it is written to local flash memory and then check-pointed to the 
standby module. Configurations can also be backed up to a workstation using the GUI or Virtual Connect 
Support Utility. 
NOTE: HP recommends saving a configuration after each session and before updating 
firmware. 