HP Virtual Connect for c-Class BladeSystem Version 2.30 User Guide

Server management 108
Column name Description
100Mb-MAX Configured speed for the network in 100-Mb increments.
PXE Shows whether PXE is enabled, disabled, or USE BIOS is selected on that
port. Only one port can have PXE enabled for VC-controlled addresses.
MAC Type of MAC address assignment configured for the Virtual Connect
domain
Delete When the X in the column is bold, this line item is eligible for deletion.
FC SAN Connections (Physical
ports)
Port Relative order of the Fibre Channel port on the server receiving the profile
Connected to Bay number of the VC-FC module to which the port is connected
FC SAN name Name of the SAN fabric to which the port is connected, or Unassigned
Status Status of the Fibre Channel module port connected to the server HBA port
Port speed Speed of the VC-FC module port connected to the server HBA port
WWPN Type of WWN address assignment configured for the Virtual Connect
domain
Delete When the X in the column is bold, this line item is eligible for deletion.
Assign Profile to Server Bay
Power Icon indicates if the server blade is powered on or off (when a server
blade is selected)
Server Bay Assignment Displays the enclosure name, bay number, and type of server blade
S/N Serial number of the server blade in the device bay
Model Model name of the server blade in the device bay
Status Status of the server blade in the device bay
UID Icon indicates if the server blade UID is on or off
The following table describes the available actions in the Define Server Profile screen. Clicking another
link in the pull-down menu or left navigation window causes current edits that have not been applied to be
lost.
Task Action
Create a profile name Enter a name in the Profile Name field.
Select to use server factory
defaults for Ethernet MAC
addresses
Click Advanced....
Select to use server factory
defaults for Fibre Channel
WWNs
Click Advanced....
Select to use factory defaults for
serial numbers (logical)
Click Advanced....