HP Virtual Connect for c-Class BladeSystem Version 2.30 User Guide
Domain management  45 
•  For Flex-10 connections, threshold and link state change traps reflect the state of the entire physical 
port. These traps are not generated for individual FlexNICs. For more information on Flex-10 
connections, see "Flex-10 overview (on page 100)." 
The following table provides a list of MIBs and where they are supported. 
MIB VC-Enet VC-FC 
RFC 2863 IF-MIB  X  — 
RFC 4188 Bridge-MIB  X  — 
RFC 3418 SNMP v2 MIB  X  X 
Compaq System Info MIB  X  X 
Compaq Host MIB  X  X 
Compaq Rack MIB  —  X* 
Network Mgmt  X  — 
IP-MIB X — 
Fibre Alliance MIB (FC Mgmt Integ)  —  X 
Fabric Element MIB  —  X 
VC Module MIB (VCM-MIB)  X  — 
VC Domain MIB (VCD-MIB)  X  — 
* Not supported by the HP 8Gb 24-Port FC module 
The VC Module MIB is a VC-specific MIB that describes the state of a specific VC module. In addition to 
unique VC module attributes, it defines traps for reporting alerts on port statistics, such as throughput, 
errors, and discards. The VC Domain MIB combines domain-wide attributes with traps for state changes in 
VC managed objects. 
The latest version of the VC-specific MIBs, 8.30b or higher, can be downloaded from the HP Systems 
Insight Manager "MIB Kit" site on the HP website 
(http://h18006.www1.hp.com/products/servers/management/hpsim/mibkit.html). 
SNMP traps 
The following table provides a summary of the available SNMP traps. 
Trap Category Severity MIB 
cpqHoSWRunningStatusChangeTrap  VCM Legacy  Corresponds to the 
new value of 
cpqHoSWRunningSt
atus 
CPQHOST-MIB 
connUnitStatusChange VC-FC Other INFO FA-MIB 
connUnitDeletedTrap VC-FC Other INFO FA-MIB 
connUnitEventTrap VC-FC Other INFO FA-MIB 
connUnitSensorStatusChange VC-FC Other  CRITICAL  FA-MIB 
connUnitPortStatusChange  VC-FC Port Status  See table below  FA-MIB 
authenticationFailure* VC-FC Other CRITICAL  SNMPv2-MIB 
coldStart VC-FC Other CRITICAL SNMPv2-MIB 
cpqHoSWRunningStatusChange VC-FC Other  INFO  CPQHOST-MIB 