HP Virtual Connect for c-Class BladeSystem Version 2.30 User Guide
Domain management  50 
Field name  Description 
Default: public 
Format  Format of the new trap. Select SNMPv1 or SNMPv2. 
To add a trap destination, right-click on the header row of the destination table, and then select Add 
Destination. See "Adding an SNMP trap destination (on page 50)." 
To edit or delete a trap destination, right-click on that trap destination row, and then select Edit 
Destination or Delete Destination. 
To apply changes made on this screen, click Apply. 
Adding an SNMP trap destination 
To add an SNMP trap destination, right-click on the header row of the SNMP Trap Destination table. 
1.  Enter a unique name for the new trap being added. No spaces are allowed. 
2.  Enter the IPv4 address or DNS name for the trap destination. 
3.  Select the Trap Format: SNMPv1 or SNMPv2. 
4.  Enter the SNMP community name string for the specified trap. The default is "public." 
For VC-Enet modules, the maximum string length is 39. 
For VC-FC modules, the maximum string length is 12. 