HP Virtual Connect for c-Class BladeSystem Version 2.30 User Guide
Storage management  89 
Number of uplinks  FC connectivity for device bays 
Uplink #5 - 5, 9 
Uplink #6 – 6, 10 
Uplink #7 - 7, 11 
Uplink #8 - 8, 12 
To form a Virtual Connect fabric correctly, participating uplinks must be connected to the same SAN 
fabric. The WWN of the principle fabric switch indicates connectivity to the same SAN fabric in Virtual 
Connect. 
The module uses Dynamic Load Balancing to provide an uplink port path failover that allows server 
connections to failover within the Virtual Connect fabric. Server connections are redistributed across all 
available (currently logged in the external SAN) uplink ports. 
Login distribution 
When creating or editing a SAN fabric, click Advanced to select the login distribution. 
•  Dynamic Login Balancing—Balances traffic based on the number of SAN logins on a port. This type 
of mapping provides failover capabilities within the Virtual Connect fabric. 
•  Static Login Distribution—Permanently maps the server connection to a specific uplink port. 