HP Virtual Connect for c-Class BladeSystem Version 3.00 User Guide for Integrity BL8x0c i2 Server Blades
Server management  100 
Only the first FlexNIC on each physical port of a Flex-10 device can be used for PXE boot. Virtual 
Connect cannot enable PXE boot on the remaining FlexNICs of a physical port. 
Redundancy for PXE operations can be achieved using multiple PXE enabled NICs. However, the Virtual 
Connect Manager is limited to enabling only one NIC for PXE booting. If a configuration requires more 
than one NIC to have PXE enabled, you should set all NICs in the VC Manager to the "Use BIOS" setting, 
and configure the NIC PXE settings through their respective BIOS utilities (F9 for embedded NICs, and F1 
for mezzanine NIC ports.) 
The following table lists examples of valid configurations for PXE enabling NIC ports. This is only a 
sampling of the possible valid configurations. 
PXE enabled  PXE disabled  Server blade configuration 
Embedded NIC 1,  
Mezz 1 NIC port 1  
Embedded NIC 2,  
Mezz NIC port 2  
BL46xc with a dual-port NIC Mezzanine 
adapter 
Embedded NIC 2,  
Mezz 1 NIC port 1 
Embedded NIC 1,  
Mezz NIC port 2  
BL46xc with a dual-port NIC Mezzanine 
adapter 
Embedded NIC 1,  
Mezz 1 NIC port 1,2 
Embedded NIC 1 
BL46xc with a dual-port NIC Mezzanine 
adapter 
Mezz 1 NIC port 1,2  Embedded NIC 1,2 
BL46xc with a dual-port NIC Mezzanine 
adapter 
Embedded NIC 1,  
Mezz 1 NIC port 1 
Mezz 2 NIC ports 1,2 
Embedded NIC 2, 3,4 
Mezz 1 NIC port 1 
Mezz 2 NIC port 3,4  
BL48xc with a dual-port NIC Mezzanine 
adapter and a quad-port NIC Mezzanine 
adapter 
Embedded NIC 4,  
Mezz 1 NIC ports 1,2 
Mezz 2 NIC ports 1,2,3,4 
Embedded NIC 1,2,3 
BL48xc with a dual-port NIC Mezzanine 
adapter and a quad-port NIC Mezzanine 
adapter 
Mezz 1 NIC port 1 
Mezz 2 NIC ports 1 
Embedded NIC 1,2,3,4 
Mezz 1 NIC port 2 
Mezz 2 NIC port 2,3,4 
BL48xc with a dual-port NIC Mezzanine 
adapter and a quad-port NIC Mezzanine 
adapter 
In each configuration above, only one embedded NIC port is allowed to have PXE enabled (any 
embedded NIC port is eligible), but any and all mezzanine NIC ports can be enabled whether or not an 
embedded NIC port is being enabled. 
For more information on RBSU, see the HP ROM-Based Setup Utility User Guide on the Documentation CD 
or the HP website (http://www.hp.com/support/smartstart/documentation
). 
Define Server Profile screen 
Use this screen to create a new server profile definition, which defines and configures Ethernet and Fibre 
Channel connectivity for the server. This screen can be edited only by users with server privileges, but it is 
viewable by all authorized users. 
IMPORTANT: The network setup wizard or equivalent steps must be performed before 
defining server profiles. See "HP Virtual Connect Network Setup Wizard" in the HP Virtual 
Connect for c-Class BladeSystem Setup and Installation Guide. 
When defining server profiles in a multi-enclosure configuration, profiles can be assigned to server bays 
in any of the enclosures that have been added and imported into the domain. 
The following table describes the fields within the Define Server Profile screen. 